14
Concrete Install Kit #CMK1 is not included
(see page 7) Contact Customer Service at
888-384-1115 to inquire about the Concrete
Installation Kit CMK1.
CAUTION:
Avoid potential personal injury or property damage!
●
Mount the wall plate assembly
08
directly onto the concrete surface
●
Minimum
solid concrete
thickness: 8 in. (203 mm)
●
Minimum
concrete block
size: 8 x
8
x 16 in. (203 x 203 x 406 mm)
●
Minimum horizontal space between fasteners: 16 in. (406 mm)
1
2
Level the wall plate template
07
and tape in place.
Drill four pilot holes.
CAUTION:
Never drill into the mortar between blocks.
IMPORTANT:
Pilot holes must be drilled to a depth of 3 in.
(75 mm), using a 3/8 in. (10 mm) diameter drill bit.
MIN.
16 in.
(406 mm)
002862.eps
STEP 2B Attach Wall Plate
Solid Concrete or Concrete Block Installation
07
07
3/8 in.
(10 mm)
3 in. (75 mm)