background image

10

Instruction Manual for HRV

1-888-726-8869

www.sanuvox.com

WARRANTY

You should first read all instructions before attempting to use this product.

For this warranty to be valid, keep a copy of the proof of purchase.

UV lamp

3 years, residential use

2 years, commercial use

Ballast

3 years

A.  This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to 

damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered 

manufacturing defects under this warranty.

 

SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.

 

Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so 

the above limitations or exclusions may not apply to you. This warranty gives specific legal rights, and you also may have other rights which vary from 

jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

B.  At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.

C.  This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D.  This warranty does not cover the filters, pre-filters or other accessories (if included), except for material or workmanship defects.

Call us toll-free at 1-888-726-8869 or email: 

info@sanuvox.com

Please be sure to specify product name.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT 

TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING 

CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

CUSTOMER SERVICE

TO ORDER REPLACEMENT PARTS

PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE

Toll-Free Phone #: 1-888-726-8869

Email: info@sanuvox.com

Website: www.sanuvox.com

Please be sure to specify product name.
Replacement parts for this product

BST120/277GL

Ballast with multi-voltage input of 120-277 VAC, 50/60 Hz

LMPHGJ105

T6 High Intensity (UVC) 10.5" ‘J’ shaped UV lamp

LMPHGJ65

T6 High Intensity (UVC) 6.5" ‘J’ shaped UV lamp

 WARNING

: Use only specified SANUVOX branded replacement UV lamps with your unit or system. 

Use of any other 

lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

Summary of Contents for HRV6

Page 1: ...he UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safety instructions out...

Page 2: ...hat s included 4 Step by Step Setup Installation 4 OPERATION 6 How to Operate your Product 6 How to Read the Signal Lights LED 6 MAINTENANCE 6 How to Replace Lamp 6 Step by Step Lamp Replacement 6 How to Clean your Product 8 STORAGE 8 ULTRAVIOLETS UVC 8 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 8 TROUBLESHOOTING 8 What you will need 8 Problems Solutions Table 8 A Step by Step UV Lamp ...

Page 3: ...ze your specific application please call SANUVOX at 1 888 726 8869 COMPONENTS How it Works Contaminated air enters the HRV parallel to the UV J Lamp thus increasing contact time with the UV energy Then the treated air circulates through the home A Aluminum Reflector Tube B Access Plate C Signal Lights LED D Ballast Box E Lamp Clamp inside the tube at the back of the access plate F Power Cord TECHN...

Page 4: ...Step by Step Setup Installation 1 Prepare the HRV for installation Remove the contents from packaging Using a flat screwdriver turn the 4 access door screws so that you can separate the assembly ballast and access door from the reflector tube CAUTION Before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more...

Page 5: ... up the pins with the holes The connector will fit into position NOTE Too much force applied from the opposite endcap may break the lamp 6 Gently replace the assembly ballast access door and lamp in the reflector tube taking care not to hit the lamp Once the assembly is in place turn the 4 tightening screws using a flat screwdriver make sure that the access plate is securely attached to the tube S...

Page 6: ...lure LED OFF No power or unit failure Lamp Ballast MAINTENANCE How to Replace the Lamp Replacing the lamp on the HRV is quick and easy Simply turn off the power source remove unit from duct remove and dispose of old lamp replace with new Sanuvox branded UV lamp replace unit in duct and turn power source back on See below for detailed step by step instructions CAUTION In order to avoid reduced perf...

Page 7: ...ure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints Fingerprints on the lamp will negatively impact the UV output of the lamp 7 Once the UV lamp is installed reinstall the assembly in the reflector tube and plug in your unit STEP 7 5 While holding the porcelain end cap with 4 pins in the clamp carefully push the white connector onto the four pins The plug is des...

Page 8: ...t 120 277 240VAC 50 60Hz The HRV6 has a power of 25 Watts and th HRV8 of 40 Watts See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUS...

Page 9: ...stalling or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnect 2 Remove the UV lamp from the lamp socket by opening the retaining clamp 3 Using an ohmmeter place 1 probe on 1 of the 4 pins and by sensing the 3 remaining pins one should have continuity Make sure the 2 remaining pins also have...

Page 10: ... SANUVOX will repair or replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll fr...