background image

4

Instruction Manual for QUATTRO

1-888-726-8869

www.sanuvox.com

SETUP & INSTALLATION

What you will need

A utility knife to unpack all components, a drill, a pair of scissors or a saw and a 1/4 nutdriver.

 CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, 

install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit 

or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.

What’s included

The QUATTRO with its UV lamps (4) and a basic installation kit.

Setup

The recommended ideal location for the installation of the purifier is the main return duct, just before the filters and the air 

conditioning coil. If there is a humidifier installed in the ductwork, make sure that the purifier is installed before the humidifier and 

that the humidifier is protected from UV rays. Should it prove impossible to install the purifier in the return line, the main supply 

line is still a suitable choice. The black control panel should be on the outside of the duct.

  CAUTION: Make sure the site can be supplied with the necessary power requirements. Ensure that there is adequate 

clearance for service and maintenance.

The installation kit includes: a UV caution decal, a maintenance decal, a warranty card and self tapping screws (12).

Step by Step Installation

1.  Turn off all power to the HVAC equipmen and prepare the QUATTRO 

for installation. Remove it from its packaging.

 

NOTE: The lamps are installed in the unit at the factory. Use caution as 

all lamps are fragile.

STEP 1

Summary of Contents for Quattro

Page 1: ...e UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safety instructions outl...

Page 2: ... s included 4 Setup 4 Step by Step Installation 4 OPERATION 6 How to Operate your Product 6 How to Read the LED Signal 6 MAINTENANCE 7 How to Replace Lamp s 7 Step by Step Lamp Replacement 7 How to Clean your Product 8 STORAGE 8 ULTRAVIOLETS UVC 8 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 9 TROUBLESHOOTING 9 What you will need 9 Problems Solutions Table 9 A Step by Step Lamp Test 9 WA...

Page 3: ... and common odors up to a 5 ton HVAC system The Sanuvox QUATTRO is installed in the RETURN preferred or SUPPLY plenum of the HVAC equipment treating 100 of the the air stream The actual percentage is based on the duct size percentage of fresh air velocity and the specific contaminants to be treated Depending on the variables above more than one QUATTRO may be required for commercial applications F...

Page 4: ...in return duct just before the filters and the air conditioning coil If there is a humidifier installed in the ductwork make sure that the purifier is installed before the humidifier and that the humidifier is protected from UV rays Should it prove impossible to install the purifier in the return line the main supply line is still a suitable choice The black control panel should be on the outside ...

Page 5: ...t a distance from 10 to 15 from the backplate To adjust the assembly loosen the clutch by turning it counter clockwise Rotate the clutch clockwise to tighten The lamps and extrusion can then be positioned to the desired distance from the backplate STEP 2 STEP 4 Extends Assembly 5 Place the QUATTRO in the duct opening in the correct position Screw unit in place on duct with the 12 self tapping shee...

Page 6: ...optimal performance air temperature moving through the unit should be in the range of 15 to 20 C 60 to 70 F How to Read LED Signal ON OFF Toggle Switch Light LIGHT OFF Unit is OFF RED LIGHT ON Unit is ON there is power When operating the LED lights on the front cover will be lit There are two LED lights corresponding to each of the 4 UV Lamps The AMBER LED lights indicate the UV lamps are function...

Page 7: ...etailed step by step instructions CAUTION In order to avoid reduced performance of lamp s do not touch lamp glass without gloves Step by Step Lamp Replacement 1 Turn off the Quattro and unplug the unit CAUTION Disconnect all power before performing any maintenance or service 2 Once the Quattro is removed from the duct remove the lamp from the reflector 4 Use a new UV lamp and plug it into the whit...

Page 8: ...cific storage It is a portable unit that works continuously when ON or automatically when selecting proper settings fan speed and timer CAUTION Keep away from unsupervised children This unit is not a toy 7 Plug the power cord into the wall outlet 8 Turn on 6 Replace the QUATTRO in the duct opening in the correct position and screw it back STEP 7 STEP 8 STEP 6 How to Clean your Product For optimal ...

Page 9: ...p is not one of the lamp is defective check the lamp to ensure that it is not a defect in the lamp sensing circuit in the ballast This is done by using an ohmmeter to check the two filaments on the lamp See A Step by Step Lamp Test instructions on page 9 Contact your contractor for all your needs in terms of replacement parts power cord circuit braker UV lamps etc TROUBLESHOOTING If your product i...

Page 10: ...inal date of purchase B At its option SANUVOX will repair or replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material o...

Reviews: