6
Instruction Manual for QUATTRO
1-888-726-8869
www.sanuvox.com
OPERATION
How to Operate your Product
The QUATTRO has an ON-OFF toggle switch and a circuit breaker located at the bottom of the front cover. The QUATTRO is
an automatic unit: once it’s installed and plugged in, simply press the power switch to turn it ON and enjoy clean air inside!
CAUTION:
The suggested operating temperature range is 4 to 66°C (40 to 150°F). Operating the QUATTRO outside this
range will result in decreased performance. For optimal performance, air temperature moving through the unit should be in the
range of 15 to 20°C (60 to 70°F).
How to Read LED Signal
ON-OFF Toggle Switch Light
LIGHT OFF:
Unit is OFF.
RED, LIGHT ON:
Unit is ON /
there is power.
When operating, the LED lights on the front cover will be lit:
There are two LED lights corresponding to each of the 4 UV
Lamps. The AMBER LED lights indicate the UV lamps are functioning. The RED LED lights indicate the ballast are ON.
Lamp #1
Lamp #2
Lamp #3
RED LED lights for ballasts
Lamp #4
AMBER LED lights for UV lamps
If a UV lamp is defective
, its ballast RED LED light will remain ON, but its
lamp AMBER LED light will be off.
If both LED lights are OFF, the ballast is not functioning.