8
Instruction Manual for SABER PRO WIRELESS 24V
1-888-726-8869
www.sanuvox.com
How to Reset your Product and its Lamp Timer
After installing a new lamp, make sure the timer function is reset.
Step by Step Product and Lamp Timer Reset
1. On the ballast, press and hold for 3 seconds the reset button until LED
blinks. The timer has now been reset.
On your LCD display, you will notice that after approximately 1 minute
the display will show ‘365 days left’ on the counter.
STEP 1
MAINTENANCE
How to Replace Lamp(s)
Replacing lamps on the SABER PRO WIRELESS 24V is quick and easy. Simply turn off the power source, remove lamp from
duct, dispose of old lamp and replace with new Sanuvox branded UV lamp, replace lamp in duct and turn power source back
on. See below for detailed step by step instructions.
CAUTION: In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.
Step by Step Lamp Replacement
1. First disconnect white socket from the old lamp. Then, loosen the 2
screws on the retainer ring and turn retainer ring counterclockwise .
Pull out the old lamp. Dispose of old lamp.
NOTE: UV lamps can be disposed/recycled after use, as any other
fluorescent lamps. Contact and follow your local and national authorities’
specific instructions.
2. Prepare the new lamp. Remove the contents from packaging. Only
after you have visually inspected the UV lamp should you break the
security seal on the underside of the cardboard sleeve.
3. Carefully slide the new
UV lamp
out from the cardboard sleeve. Be sure
to wear the cotton gloves (included) guaranteeing a clean lamp free
from fingerprints. Fingerprints on the lamp will negatively impact the UV
output of the lamp.
STEP 1
STEP 2
STEP 3