background image

8

Instruction Manual for SABER PRO WIRELESS 24V

1-888-726-8869

www.sanuvox.com

How to Reset your Product and its Lamp Timer

After installing a new lamp, make sure the timer function is reset.

Step by Step Product and Lamp Timer Reset

1.  On the ballast, press and hold for 3 seconds the reset button until LED 

blinks. The timer has now been reset.

 

On your LCD display, you will notice that after approximately 1 minute 

the display will show ‘365 days left’ on the counter.

STEP 1

MAINTENANCE

How to Replace Lamp(s)

Replacing lamps on the SABER PRO WIRELESS 24V is quick and easy. Simply turn off the power source, remove lamp from 

duct, dispose of old lamp and replace with new Sanuvox branded UV lamp, replace lamp in duct and turn power source back 

on. See below for detailed step by step instructions.

 CAUTION: In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

Step by Step Lamp Replacement

1.  First  disconnect  white  socket  from  the  old  lamp. Then,  loosen  the  2 

screws on the retainer ring and turn retainer ring counterclockwise  . 

Pull out the old lamp. Dispose of old lamp.

 

NOTE:  UV lamps can be disposed/recycled after use, as any other 

fluorescent lamps. Contact and follow your local and national authorities’ 

specific instructions.

2.  Prepare the new lamp. Remove the contents from packaging. Only 

after you have visually inspected the UV lamp should you break the 

security seal on the underside of the cardboard sleeve.

3.  Carefully slide the new 

UV lamp

 out from the cardboard sleeve. Be sure 

to wear the cotton gloves (included) guaranteeing a clean lamp free 

from fingerprints. Fingerprints on the lamp will negatively impact the UV 

output of the lamp.

STEP 1

STEP 2

STEP 3

Summary of Contents for SABER PRO WIRELESS 24V

Page 1: ... own expense 5 Follow all the safety instructions outlined in this document and respect all local and national codes applicable 6 Never expose eyes or skin to ultraviolet light from any source Therefore before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnect CAUTION Electrica...

Page 2: ...Ballast Display 7 How to Read the LCD Wireless Display 7 How to Reset your Product and its Lamp Timer 8 Step by Step Product and Lamp Timer Reset 8 MAINTENANCE 8 How to Replace Lamp s 8 Step by Step Lamp Replacement 8 How to Clean your Product 9 STORAGE 9 ULTRAVIOLETS UVC 9 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 9 Regulations of the LCD Wireless Display 9 TROUBLESHOOTING 10 What yo...

Page 3: ...a loss in energy efficiency as the equipment must work harder to provide the same air temperature Installed on the air conditioning s evaporator coil the SABER PRO WIRELESS 24V keeps the system running at top efficiency saving you electricity and preventing the coil from becoming a source of bad air quality and bad odor A 16 UVC Lamp B Main Bracket C Magnetic Multi Bracket D Lamp Retaining Ring E ...

Page 4: ...ed The ballast the LCD wireless display with 2 AA batteries 2 UV lamps and a basic installation kit The installation kit includes a UV caution decal a maintenance decal a pair of cotton gloves screws a plastic view port the main bracket a magnetic multi bracket and a lamp retainer ring Step by Step Setup Installation Check out Sanuvox Technologies YouTube Channel for the SABER PRO WIRELESS 24V ins...

Page 5: ...nly be installed one way You may have to rotate the socket 90 to line up the pins with the holes STEP 3 STEP 4 STEP 5 STEP 6 5 Drill a 0 25 hole on the outside of the plenum and install the view port When the lamp is ON the glow of the lamp will be visible through this port 6 Connect the two black wires to the 24VAC terminals on the HVAC equipment NOTE Make sure that the HVAC equipment can at leas...

Page 6: ...11 10 Finally you need to place the LCD display in a proper location for efficient communication between the display and the ballast Both communicate wirelessly in a range of up to 60 feet NOTE Don t put the LCD display on a metallic duct 11 Before mounting the LCD display to a wall first make sure there is a connection between the ballast and the display at desired location If the distance is too...

Page 7: ...system OK FLASHING RED once every second Lamp 8 700 h time to replace the lamp FLASHING RED twice every second Lamp failure FLASHING RED three times every second Ballast failure FLASHING RED four times every second Low voltage under 18V FLASHING RED five times every second High voltage over 30V Connects to a Step Down Transformer sold separately How to Read the LCD Wireless Display The SABER PRO W...

Page 8: ...e below for detailed step by step instructions CAUTION In order to avoid reduced performance of lamp s do not touch lamp glass without gloves Step by Step Lamp Replacement 1 First disconnect white socket from the old lamp Then loosen the 2 screws on the retainer ring and turn retainer ring counterclockwise Pull out the old lamp Dispose of old lamp NOTE UV lamps can be disposed recycled after use a...

Page 9: ... comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Ho...

Page 10: ...empt to restart the ballast Shut the power to the ballast hard reset wait 10 seconds and turn the power back ON Check power source to confirm that it is within specifications on product label Get a replacement ballast Error Code 4 EC4 Voltage to the ballast is less than 18VAC Power source furnace control panel or transformer does not provide sufficient power output measured in VA Measure the volta...

Page 11: ...also have continuity The 4 pins are in a rectangle pattern The 2 pins that form the 2 short sides of the rectangle are the pins that have continuity through the lamp element 1 Remove the LCD display cover by pressing the tab located at the bottom of the LCD display with a flat head screwdriver Separate the cover from the housing 2 With the LCD display cover removed press the black button to enter ...

Page 12: ...replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters UV bulbs or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726...

Reviews: