background image

5

Instruction Manual for SANUVAIR

®

 S100

1-

778-877-3454

www.

blueg

old

labs

.com

8.

Now, prepare location for installation:

 Cut a 24" x 14" opening in a

suspended ceiling tile

 to install the unit. In order to facilitate the work,

remove 14" lengthwise.

9. Connect the power supply to the adapter, and the adapter to the unit.

NOTE:

 Once connected, the unit will turn on automatically. Continue

with the installation while the unit is running.

STEP 8

STEP 9

STEP 10

STEP 11

10. Make sure to position the unit so that the air outlet (open end) is at least

24" from the wall.

Pass the unit through the ceiling (tilt it slightly to the side) and gently

lean the device support anchors against the tile and the ceiling support.

11. Replace the cut part of the suspended ceiling tile to hide the opening. 

Then, right up against the unit, install a 24" ‘T’ bracket.

Your new SANUVAIR

®

 S100 is now ready to

operate so you can enjoy great air quality 

for you and your colleagues.

6. Install Filter:

 While the unit cover is still open, pull on the non-mesh

end to gain access to the filter location (mesh door). Take the filter out

of its packaging and install it in the unit. Close the mesh door properly.

7. Adjust the fan speed: While the unit cover is still open, you will have

access to the speed controller. For best results, choose “Hi” and for

quieter use, choose “Low”.

Once the lamp and filter are installed and the fan settings are adjusted

to your liking, make sure to 

close the unit cover properly.

STEP 7

STEP 6

Summary of Contents for SANUVAIR S100GX

Page 1: ...evail on those of this document and the installer agrees to conform to these at his own expense 7 Follow all the safety instructions outlined in this document and respect all local and national codes applicable 8 This unit contains a UV C emitter Unintended use of the unit or damage to the housing may result in harmful UV C radiation leaks UV C radiation may even in little doses cause harm to the ...

Page 2: ...ep Setup Installation Ceiling Mounted 4 Step by Step Setup Installation Wall Mounted 6 OPERATION 7 How to Operate your Product 7 MAINTENANCE 8 How to Replace Lamp s 8 Step by Step Lamp Replacement 8 How to Clean your Product 9 Step by Step Filter Cleaning 9 STORAGE 10 ULTRAVIOLETS UVV UVC 10 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 10 TROUBLESHOOTING 10 What you will need 10 Problems...

Page 3: ...n internal fan circulates air through the air purifier The SANUVAIR S100 is designed to treat up to 500 square feet of space per unit A Air inlet vent B Filter door with mesh C Security switch D Filter E UV Lamp F Fan G Unit cover H Air outlet vent SETUP INSTALLATION What you will need A utility knife to unpack all components a stepladder to reach the celling or wall properly a Phillips No 2 screw...

Page 4: ... unit out of its box and install the support anchors required to support the unit by screwing them directly to the unit A Sliding door side near horizontal support bracket B Beveled side mesh angled support bracket Then lay the unit on a flat surface with the access doors facing up NOTE Keep box in case of return under warranty STEP 1 STEP 2 STEP 5 5 Install lamp Open the unit by sliding its cover...

Page 5: ...he device support anchors against the tile and the ceiling support 11 Replace the cut part of the suspended ceiling tile to hide the opening Then right up against the unit install a 24 T bracket Your new SANUVAIR S100 is now ready to operate so you can enjoy great air quality for you and your colleagues 6 Install Filter While the unit cover is still open pull on the non mesh end to gain access to ...

Page 6: ...ected the UV lamp should you break the security seal on the underside of the cardboard sleeve 4 Carefully slide the UV lamp out from the cardboard sleeve Be sure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints NOTE Fingerprints on the lamp will negatively impact the UV output of the lamp STEP 3 STEP 4 STEP 5 STEP 6 5 Install lamp Open the unit by sliding its cov...

Page 7: ... the fan settings are adjusted to your liking make sure to close the unit cover properly OPERATION How to Operate your Product If wired directly to a dedicated power source the SANUVAIR S100 will operate continuously If wired in parallel with other devices such as overhead lighting the SANUVAIR S100 will operate only when the circuit is energized The internal fan circulates air through the device ...

Page 8: ...ption is preferable for a wall unit 1 Open the unit by sliding down its cover to gain access to the lamp location NOTE Unit must be disconnected from the supply before replacing lamp 3 Prepare the new lamp Remove the contents from packaging Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve 4 Carefully slide the new UV lam...

Page 9: ...oved for cleaning while the unit is installed on the ceiling or wall Another option is to remove the unit from the ceiling or wall and then access the filter with the unit lying on a flat surface with the access doors facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover and pull on the non mesh end of the filter door to gain access to the filter loc...

Page 10: ...HE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT TROUBLESHOOTING If your product is not working properly refer to the following What you will need A stepladder to reach to celling or wall properly and an ohmmeter Problem Possible...

Page 11: ...ors facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover to gain access to the lamp location 3 Using an ohmmeter place 1 probe on 1 of the 4 pins and by sensing the 3 remaining pins one should have continuity Make sure the 2 remaining pins also have continuity When both sets of pins test good for continuity it can be assumed that the lamp is good ST...

Page 12: ...o be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please be sure...