background image

3

 

WARNING

 

Before installing or performing maintenance on the unit, TURN OFF and disconnect unit from power source. 

Electrical shock may cause personal injuries or possibly death.

Never expose eyes or skin to ultraviolet light from any source. he UV puriier MUST be DISCONNECTED 

from power source before performing maintenance of service. Personal injury may result.

Do not touch lamp glass without gloves. Reduced performance of lamp may result. Clean lamp ater handling.

he UV lamp contains a small quantity of mercury. If a lamp breaks, clean and dispose of with care.

Use only speciied replacement lamps with your unit. Use of an incorrect lamp can result in damage  

to the unit and/or lamp and will also void the warranty.

When applicable local regulations comprises more restrictive installation and/or certiication requirements,  

the aforementioned requirements prevail on those of this document and the installer agrees to conform to these 

at his own expense.

When performing installation, servicing or cleaning the UV puriier, it is recommended to wear safety glasses 

and gloves.

IMPORTANT SAFETY INSTRUCTIONS

 

NOTICE 

UV lamp can be disposed / recycled ater use as any other luorescent lamp.  

Contact and follow your local and national authorities’ speciic instructions.

  

 

Component Warranty

UV lamp 

3 years

Ballast 

3 years

Electronics (circuit board) 

3 years

WARRANTY 

he warranty applicable to the diferent components included in your purchase are as per the table below:

Make sure to keep a copy of your proof of purchase in order for the warranty to be valid.

Summary of Contents for SRMax

Page 1: ...L INJURIES OR DAMAGED UNIT Installation and servicing of equipment can be hazardous Only trained and qualiied service personnel should install repair or service equipment Follow national and local safety codes Always wear safety glasses and work gloves for protection SANUVOX TECHNOLOGIES INC 146 rue Barr St Laurent Quebec Canada H4T 1Y4 1 888 SANUVOX www sanuvox com ...

Page 2: ...x at 1 888 SANUVOX Only with LMPRGXJ65 UV lamp Table of Contents About the SRMax GENERAL Installation and servicing of air conditioning and related equipment can be hazardous due to system pressure and electrical components Only trained and accredited service personnel should install repair or service such equipment Untrained personnel can perform basic maintenance functions such as replacing lamp...

Page 3: ... and or lamp and will also void the warranty When applicable local regulations comprises more restrictive installation and or certiication requirements the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense When performing installation servicing or cleaning the UV puriier it is recommended to wear safety glasses and gloves ...

Page 4: ...otton gloves Metal screws for cover Qty 4 Phillips screws for frame Qty 6 8 32 screws for turbulator Qty 2 Frame Turbulator INCLUDED IN THE BOX he SRMax you purchased includes the following For information or recommendations to size appropriately your speciic application please call Sanuvox at 1 888 SANUVOX ...

Page 5: ...et is Telon coated which makes it resistant to UV exposure he SRMax relecting chamber has to be installed parallel to the airlow with the turbulator upstream to slow down the air as it moves in front of the UV lamp he suggested operating temperature range is 10 to 50 C 50 to 120 F Operating the SRMax outside this range will result in decreased performance For optimal performance air temperature mo...

Page 6: ... the UV lamp Insert the lamp connector over the 4 pins of the UV lamp 1 5 Reinstall the relecting tube by making sure that the turbulator is facing the airlow so that it will slow down the air as it passes in front of the UV lamp 2 Prepare the duct return or supply for installation 2 1 Evaluate the ideal area for installing the air puriier he relection chamber should always be parallel to the air ...

Page 7: ... to where the SRMax is installed 3 4 You are now ready to power ON your new SRMax and enjoy great air quality for you and your family GREEN In operation ORANGE Heartbeat followed by 1 lash lamp over 3 years that needs to be replaced BLUE Heartbeat stand by waiting for airlow INFORMATION FROM THE STATUS LED Normal operation BLUE Airlow detection activated WHITE Factory setting airlow detection de a...

Page 8: ...y mode when the unit is plugged in and the power switch is ON will leave the lamp ON at all times in order to reduce the cycling strain on the lamp and improve its life It is possible to activate the airlow detection if required he activation procedure is the following 1 If your unit is powered ON start by turning OFF the power switch 2 Use a small object similar to a paper clip and insert it into...