Page 10
FEaTURES FaMiLiaRizaTiOn
Low Voltage Alert Alarm
The Low Voltage Alert alarm will sound when the transmitter batteries reach the Alert
Voltage value programmed in the SYSTEM - ALARM menu. The alarm will sound each
time the transmitter battery voltage decreases by 0.1 volt. To clear this alarm, press the
Back/Cancel key or the Push-Button Rotary Dial. For more information, see the
Voltage
Alarm
section on pages 64 and 65.
TRanSMiTTER SaFETY aLaRMS anD LED cOnDiTiOn inDicaTORS, cOnTinUED....
Temperature Alert Alarm
The Temperature Alert alarm will sound when the TEMP1 and/or TEMP2 temperature
reaches the Alert Temperature value programmed in the SYSTEM - TELEMETRY menu.
To clear this alarm, press the Back/Cancel key or the Push-Button Rotary Dial. For more
information, see the
Changing the Alert Temperature Value
section on page 67.
Voltage Alert Alarm
The Voltage Alert alarm will sound when the receiver battery in your model reaches the
Alert Voltage value you've programmed in the SYSTEM - TELEMETRY menu. To clear
this alarm, press the Back/Cancel key or the Push-Button Rotary Dial. For more information,
see the
Changing the Alert Voltage Value
section on pages 68 and 69.
Blue
Blue
Blue
Blue
Red
Red
Red
Blue and Red
Blue and Red
Blue and Red
Blue and Red
RF Output Signal OK
Throttle Offset Value ON with Positive or Negative Value Programmed
Telemetry Logger Function Operating
Anti-Lock Braking Function Operating
No Transmitter/Receiver Telemetry Connection
Telemetry Alarm Started
Low Voltage Alert Alarm Started
Bind Command Transmitted
Inactivity (Power ON) Alarm Started
Low Voltage Limit Alarm Started
Over Voltage Alarm Started
LED COLOR
LED CONDITION DESCRIPTION
LED CONDITION
ON
Flash
Slow Flash
Fast Flash
ON
Flash
Flash
Flash Alternately
Flash
Fast Flash Alternately
Fast Flash Alternately
Inactivity (Power ON) Alarm
The Inactivity Alarm will sound if the transmitter is left on for a period of 10 minutes without
any control input from the user. This alarm alerts you to prevent unwanted draining of
the transmitter battery. To clear this alarm, either turn the transmitter 'OFF' or press the
Back/Cancel key or the Push-Button Rotary Dial.
Low Voltage Limit Alarm
The Low Voltage Limit alarm will sound when the transmitter batteries reach the Limit Volt-
age value programmed in the SYSTEM - ALARM menu. This alarm can only be cleared by
turning the transmitter 'OFF' and recharging or replacing the transmitter batteries. For more
information, see the
Voltage Alarm
section on pages 64 and 65.
LED Condition Indicators
LED 1 (Blue) and LED 2 (Red) can be used to determine various transmitter conditions at a glance. The LEDs will alert you to
various warnings and other transmitter conditions, as shown in the table below.