Operation
Safety, Operation and Maintenance Manual - Sep 2012
4-22
SY115C9/135C/155H Crawler Hydraulic Excavator
4.2 Engine Starting
Note:
●
Before starting the engine, check that the
fuel control dial (2) is in MIN position for
low idling speed. If the knob is in MAX po-
sition, starting the engine can lead to sud-
den acceleration and damage to its parts.
●
Never keep the ignition key in START
position for more than 20 seconds.
If the engine fails to start, wait at least two
minutes before restarting it.
●
After the engine is started, operation is not
allowed until oil pressure stays in the nor-
mal range. Never manipulate any control
lever or pedal in case of abnormal oil pres-
sure.
●
Always start the engine from the opera-
tor seat.
●
Never start the engine in a way that
may cause short circuit, which can lead
to serious injury or
fi
re.
●
Sound the horn and start the engine
after you have confirmed that the sur-
rounding area is clear of personnel or
barriers.
●
Never use start-assisting solution as
which may cause explosion.
●
Exhaust gas is poisonous. Pay special
attention to keeping a good ventila-
tion when starting the engine in an en-
closed space.
1
2
3
CZ335S-1103062
WARNING
Fig. 4-36