4. Turn the ignition key to START position (C).
5. Release the key (3) after starting the
engine. The key will be back to the ON
position (B) by itself.
Remark:
When ambient temperature is low, the engine
may fail to start after the start switch is kept at
START position for more than 10 seconds. In
this case, wait at least for 1 minute before re-
starting the engine.
6. Wait until engine oil pressure alarm is
reset even if the engine is started. Never
maneuver any control lever or pedal when
engine oil is abnormal.
Note:
If oil pressure remains abnormal after 4-5
seconds, immediately shut down the engine,
check oil level and check for oil leak. Take
necessary actions in case of abnormality.
Fig. 4-40