Maintenance
Safety, Operation and Maintenance Manual - Aug 2012
5-33
SY115C9/135C/155H Crawler Hydraulic Excavator
Note:
The latches (2) and housing of air cleaner
could be damaged when you insert filter ele-
ment with expanded rubber on the top or you
did not push it in vertically but latch the cover
(3) with force. So be careful when you reas-
semble
fi
lter element.
12. Install the cover (3) according to the follow-
ing steps.
1) Align the cover (3) with the
fi
lter.
2) Let the end of latch (2) catch the
fl
ange
of the air cleaner housing.
3) To lock the latches (2), engage the
latches in a diagonal sequence (top -
bottom - left - right) like tightening the
bolts.
4) The vacuum valve (4) shall face toward
the ground (A) when installing the cover
(3).
5) When the cover (3) is installed, inspect
the air cleaner housing shall not have
a larger clearance with the cover (3).
Reinstallation is necessary in case of
larger clearance.
2
CZ135B-1104002
3
4
A
2
CZ135B-1104003
Fig. 5-11
Fig. 5-12