Troubleshooting
Safety, Operation and Maintenance Manual - Aug 2012
6-33
SY115C9/135C/155H Crawler Hydraulic Excavator
"LOCKED" position.
●
Check the control levers whether they are
in the neutral position.
6.8.3.1 Connecting the jumper cables
Turn the start switches of the normal machine
and the faulty machine to the OFF position.
Connect the jumper cables in the numbered
sequence, as shown in the diagram.
1. Connect the clip of jumper cable (A) to the
positive terminal (+) of battery (C) of the
faulty machine.
2. Connect the clip on the other end of jumper
cable (A) to the positive terminal (+) of bat-
tery (D) of the normal machine.
3. Connect the clip of jumper cable (B) to the
negative terminal of battery (D) of the nor-
mal machine.
4. Connect the clip on the other end of jumper
cable (B) to the swivel frame (E) of the faulty
machine.
Fig. 6-24
2
3
D
C
E
B
A
1
4
CZ335-1103222