Fuel System
Drain the Fuel Tank
NOTE:
Use diesel fuel to clean the inside of the fuel tank. Never use trichloroethane to clean the fuel tank.
1. Prepare the machine for service. See “Maintenance
NOTE:
For fuel capacity, see “Fluid Capacities” on
page 5-9.
2. Locate the fuel drain valve (2) under the right side of
the machine. Place a suitable container under the valve
to collect drained fuel.
3. Open the fuel drain valve to drain water and sediment
accumulated on the bottom of the tank. Do not allow
the fuel to splash out of the container.
4. Close the valve when only clean fuel drains from the
fuel tank.
5. If the fuel tank is completely drained, the system must be bled after refilling. See “Bleed the Fuel System” on
Bleed the Fuel System
NOTE:
Air trapped in the fuel system may cause engine starting failure or abnormal running.
After servicing the fuel system or running out of fuel, the key switch should be turned to ON for 2 to 3 minutes
before attempting to start the engine. The lift pump will bleed air from the system.
WARNING!
•
Components and oil remain hot when the engine is stopped, which may cause severe
burns. Wait until components and oil are cool before you proceed.
•
Never service the fuel system near an open flame or while smoking.
•
Fuel that comes into contact with hot surfaces or electrical components can cause a fire.
Clean up any fuel spills immediately.
Failure to follow these warnings could result in death or serious injury.
NOTICE!
Dispose of contaminated fuel or water in accordance with all applicable environmental
regulations. Failure to do so could damage the environment.