SY35U Excavator OMM
Maintenance
SANY
Operation and Maintenance Manual — 0120
5-29
TABLE OF
CONTENTS
INTRODUCTION
SAFETY
MACHINE
CONTROLS
MACHINE
OPERA
TION
MAINTENANCE
SPECIFICA
TIONS
OPTIONAL
EQUIPMENT
Replacing a Fuse
Fig. 5-22
0002998
K13
K5
K7
K8
K6
K3
K9
K12
1
2
1. Use the fuse removal and installation tool (1) to pull a
blown fuse and install a new fuse.
2. Spare fuses (2) can be used for replacing a blown fuse.
Always replace a fuse with a fuse of the same
amperage rating.
Fuse Circuits
Relay Circuits
Contact a SANY dealer for troubleshooting electrical problems
with the machine.
Fuse
Amperage
Circuit
F1
25A
Starting
F2
10A
Battery charging
F3
15A
Cab dome light, horn, and
accessory light
F4
25A
Work light
F5
15A
Washer, beacon wiper, and radio
F6
5A
HVAC control panel
F7
10A
Global positioning system (GPS)
F8
20A
HVAC system fan
F9
10A
Power outlet (12V)
F10
10A
AC compressor
F11
25A
Monitor controller
F12
25A
Fuel pump
F13
20A
Reserved for future circuit
F14
15A
Reserved for future circuit
Relay
Amperage
Circuit
K3
12V/35A
Starting
K5
12V/35A
Horn
K6
12V/35A
Work lights
K7
12V/35A
Cold weather starting
K8
12V/35A
Monitor power down
K9
12V/35A
Spare
K12
12V/35A
HVAC system fan
K13
12V/35A
AC compressor