Maintenance
SY35U Excavator OMM
5-48
Operation and Maintenance Manual — 0120
SANY
Replace the Secondary Fuel Filter
1. Prepare the machine for service. See “Maintenance
2. Place a container under the fuel filter (1) to collect
spilled fuel.
3. Remove the fuel filter with a filter wrench.
NOTE:
Always use SANY-approved fuel filters.
4. Clean the mounting base of the fuel filter and fill the
new fuel filter with clean fuel. Apply a thin film of oil
to the O-ring and install the new fuel filter onto the
filter housing.
5. When the fuel filter O-ring touches the filter housing,
turn the fuel filter an additional 1/2 turn. Overtightening
the filter may damage the O-ring, resulting in a fuel leak.
6. Turn the key switch to the ON position for 2-3 minutes before attempting to start the engine. The lift pump will
bleed air from the system.
7. Start the engine and check the fuel filter for leaks.
WARNING!
•
Components and oil remain hot when the engine is stopped, which may cause severe
burns. Wait until components and oil are cool before you proceed.
•
Never service the fuel system near an open flame or while smoking.
•
Fuel that comes into contact with hot surfaces or electrical components can cause a fire.
•
Clean up any fuel spills immediately.
Failure to follow these warnings could result in death or serious injury.
NOTICE!
•
Cleanliness is important when working with an open fuel system. Contaminated fuel can
result in engine damage.
•
Dispose of fuel and filter in according to all applicable environmental regulations.
Failure to follow this notice could damage the environment.
Fig. 5-48
0003773
1