Maintenance
SY35U Excavator OMM
5-54
Operation and Maintenance Manual — 0120
SANY
Remove the Battery
1. Prepare the machine for service. See “Maintenance Safety” on page
2. Open the engine hood (1). See “Opening the Engine
3. Open the right rear access door (2). See “Opening the
Right Rear Access Door” on page
NOTE:
Allow several minutes for any accumulated
battery gases to clear before servicing the
battery.
4. Turn the battery disconnect switch (3) to the OFF
position.
WARNING!
Before proceeding with any battery maintenance procedure, observe the following:
•
The top of the battery must be kept clean to prevent plugging of the battery vents.
Regularly wash the top of the battery to prevent the battery vents from plugging.
•
Battery gases are explosive. Never smoke around batteries or expose them to sparks or
open flames. Work in a well-ventilated area.
•
Wear personal protective equipment (PPE) when working with batteries.
•
Battery acid can cause burns or injury. If battery acid makes contact with your skin or eyes,
flush the area immediately with fresh water and seek medical attention.
Failure to follow these warnings could result in death or serious injury.
NOTICE!
After machine shutdown, wait at least 1 minute for the engine control module (ECM) to
complete its shutdown before disconnecting the battery.
Failure to follow this notice can damage the machine or cause it to operate improperly.
Fig. 5-54
0003770
1
2
3