Maintenance
SY35U Excavator OMM
5-72
Operation and Maintenance Manual — 0120
SANY
Check and Add Final Drive Oil
1. Prepare the machine for service. See “Maintenance
2. Park the machine to position the drain plug (3) at the
bottom of one of the final drives.
3. Wait 10 minutes for the final drive oil to cool.
4. Slowly loosen the oil level plug (2) to relieve any
internal pressure.
5. The oil should be at or near the lower edge of the oil
level plug opening.
NOTE:
Refer to “Recommended Lubricants, Fuels,
and Engine Coolant” on page 5-10 for the
recommended final drive oil.
6. If necessary, remove the fill plug (1) and add oil.
7. Install the oil level and fill plugs and tighten to 12.5 lb-ft (17 N•m).
8. Repeat this procedure on the other final drive.
CAUTION!
•
Allow the final drive to cool before servicing. Hot oil may cause burns or other serious
injury.
•
Wear safety goggles, gloves, and other personal protective equipment (PPE) to prevent
serious injury.
•
The final drive oil may be under pressure. Remove the plugs slowly to prevent injury.
Failure to follow these cautions could result in injury.
NOTICE!
Dispose of used oil in accordance with all applicable environmental regulations.
Failure to do so could result in damage to the environment.
Fig. 5-81
0003128
2
3
1