Maintenance
SY50U Excavator OMM
5-48
Operation and Maintenance Manual — 0120
SANY
4. Clean around the hydraulic tank breather assembly (1).
5. Remove the four fasteners (2) and the hydraulic tank
breather assembly.
6. Slowly add hydraulic oil through the breather assembly
opening of the hydraulic tank. Monitor the oil level as
it is added. See “Check the Hydraulic Oil Level” on
page
7. Install the hydraulic tank breather assembly.
Replace the Hydraulic Tank Breather Filter Element
1. Prepare the machine for service. See “Maintenance
2. Open the right front access door.
3. Clean around the hydraulic tank breather assembly (4).
4. Remove the wing nut cover (1) and press the relief
valve button (2) to release pressure in the hydraulic
tank.
5. Remove and clean the cover (3).
WARNING!
•
Allow the hydraulic system to cool before servicing. Hot oil may cause burns or other
serious injury.
•
The hydraulic tank may be under pressure, and hydraulic oil may be present at the
breather. Relieve any pressure to prevent injury.
Failure to follow this warning could result in death or serious injury.
Fig. 5-39
0003132
1
2
Fig. 5-40
0003126
2
1
4
3