MAINTENANCE
5-27
SY60C Excavator OMM
0003012
Figure 5-35
1.
Prepare the machine for service. See “Maintenance
Safety” on page 2-5.
2.
Open the engine hood and right rear access door.
NOTICE!
Open and close the fuel shutoff and drain valves
by hand. Never use tools to open or close the
valves.
3.
Turn the fuel shutoff valve (1) to OFF.
4.
Route the drain hose (2) into a suitable container.
5.
Open the drain valve (3) and drain the fuel water
separator.
6.
Close the drain valve.
7.
Remove the filter housing (4).
8.
Remove filter element (5) from the filter housing.
9.
Clean the filter housing with clean fuel.
NOTE:
Always use SANY-approved fuel filters.
10. Replace the filter element and make sure it is
securely seated within the filter housing and fill the
filter housing with clean fuel.
11. Reinstall the filter housing.
12. Turn the fuel shutoff valve (1) to the ON position.
13. Turn the key switch to ON for 2 to 3 minutes before
attempting to start the engine. The lift pump will
bleed air from the system.
14. Start the engine and check for leaks.
Batteries
Check the Batteries
WARNING
Before proceeding with any battery maintenance
procedure, observe the following:
• The top of the battery must be kept clean to
prevent plugging of the battery vents. Regularly
wash the top of the battery to prevent the battery
vents from plugging.
• Battery gases are explosive. Never smoke
around batteries or expose them to sparks or
open flames. Work in a well-ventilated area.
• Wear personal protective equipment (PPE) when
working with batteries.
• Battery acid can cause burns or injury. If battery
acid makes contact with your skin or eyes, flush
the area immediately with fresh water and seek
medical attention.
Failure to follow these warnings could result in
death or serious injury.
NOTICE!
After machine shutdown, wait at least 1 minute for
the Engine Control Module (ECM) to complete its
shutdown before disconnecting the batteries.
Failure to observe and follow this notice can
cause damage to the machine or cause the
machine to operate improperly.
1.
Prepare the machine for service. See “Maintenance
Safety” on page 2-5.
2.
Open the right front access door and turn the battery
disconnect switch to OFF. See “Battery Disconnect
Switch” on page 3-21.
0003208
Figure 5-36
1.
Remove the fasteners (1) securing the
battery cover (2). Remove the battery cover.
2
3
1
4
5
1
2