The LAN interface card (option) is used when managing the UPS power supply or shutting down the computer via LAN. For details on
the connection and setup method, see the instruction manual and user guide of the LAN interface card.
Network Configuration Example When LAN Interface Card Is Used
Step
Description
Remarks
1
1
Prepare the following:
The LAN interface card and power supply
management software “SANUPS
SOFTWARE” are options. For option details,
contact your sales representative or SANYO
DENKI.
When you want to use power management
software and are using the LAN interface card,
use the power management software
“SANUPS SOFTWARE” corresponding to the
network. One license is required per computer.
2
2
If the UPS is running, stop the UPS by performing the procedure in “4.2.2
Shutting Down the UPS”.
Unplug the UPS input plug from the outlet or turn
the outlet breaker OFF, and shut down the UPS.
Failure to completely shut down the UPS may result
in electrical shock.
3
3
Install the LAN interface card in the UPS following the procedure below.
3-1 Remove the optional card slot cover on the back of the UPS.
3-2 Insert the LAN interface card into the optional card slot, and secure the card
with screws.
3-3 Connect the UPS “CARD I/F” connector and the “UPS” connector of the
LAN interface card using the LAN interface card communication cable.
Back of UPS
4
4
Verify that “Interface” in the setting menu is set to “WS” (work station) (default
setting).
For how to operate setting menu items, see the
Setting Menu Manual.
5
5
Run the UPS in accordance with the system.
Check operation before actual use.
FE
UPS
ACT
LNK
EXT
HUB
UPS
電源ライン
LANケーブル
LAN interface card
LAN interface card communication cable
(Supplied with LAN interface card)
Power management software
SANUPS SOFTWARE
If you use the LAN interface card, you cannot do
the following simultaneously.
• Connect the supplied communication cable to
use power management software.
• Use the contact interface card (option).
The UPS backup time rating is 3 minutes.
When the LAN interface card is to be used, use in
either of the following states.
• Set the time until UPS output stops (power
outage verification time, shutdown delay time,
UPS automatic shutdown time) to within 3
seconds during a power outage.
• Use the software at a load level of 85% or less.
Note
Connect using the
communication cable.
Remove the two screws on
the left and right, and remove
the cover. Secure the LAN
interface card using the two
screws that secured the
cover.
Power line
LAN cable