-26-
After replacing the Power Board, PF.C. Board, readjust
the Output voltage adjustment as follows.
1. Connect a digital voltmeter to pins 1 (+) and 3 (-) of
K6D
.
2. Adjust the voltage by using
VR611
as following.
AC Input
Reading
230V 370V
±2V
or 120V
340V
±2V
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
●
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the follow-
ing adjustments except requiring the readjustments in servicing otherwise it may cause loss of per-
formance and product safety.
[Adjustment Condition]
●
Input signal
Video signal .......................... 1.0Vp-p/75
Ω
terminated, 16 steps gray scale (Composite video signal)
Computer signal...................... 0.7Vp-p/75
Ω
terminated, 16 steps gray scale pattern (XGA)
●
Picture control mode ...................... “STANDARD” mode unless otherwise noted.
Note:
* Please refer to “Service Adjustment Menu Operation” for entering to the service mode and adjusting the service
data.
Electrical Adjustments
Output Voltage adjustment
1. Receive the 16-step grey scale video signal.
2. Set to
VIDEO
mode.
3. Enter the service mode.
[R-PEDESTAL ADJUSTMENT]
4. Connect an oscilloscope to test point “
TP201R
” (+)
and chassis ground (-).
5. Select group no. “
3
”, item no. “
14
” and change data
value to adjust the pedestal level and black level to be
the same level.
[G-PEDESTAL ADJUSTMENT]
6. Connect an oscilloscope to test point “
TP201G
” (+)
and chassis ground (-).
7. Select group no. “
3
”, item no. “
15
” and change data
value to adjust the pedestal level and black level to be
the same level.
[B-PEDESTAL ADJUSTMENT]
8. Connect an oscilloscope to test point “
TP201B
” (+)
and chassis ground (-).
9. Select group no. “
3
”, item no. “
16
” and change data
value to adjust the pedestal level and black level to be
the same level.
Pedestal level = Black level
(a)
Pedestal adjustment
1. Enter the service mode and select group no. “
11
” and
item no. “
0
”. Set data value to “
1
”.
2. Connect a digital voltmeter to test point “TP12V1” (+)
and chassis ground (-). Select item no. “
1
” and change
data value to adjust voltage to be 8.0 ±0.1V.
3. Connect a digital voltmeter to test point “TP12V2” (+)
and chassis ground (-). Select item no. “
2
” and
change data value to adjust voltage to be 9.0 ±0.1V.
4. Select group no. “
11
” and item no. “
0
” and set data
value to “
3
”.
5. Connect a digital voltmeter to test point “TP12V1” (+)
and chassis ground (-). Select item no. “
3
” and change
data value to adjust voltage to be 13.0 ±0.1V.
6. Connect a digital voltmeter to test point “TP12V2” (+)
and chassis ground (-). Select item no. “
4
” and change
data value to adjust voltage to be 13.5 ±0.1V.
Fan Voltage adjustment
Summary of Contents for 1 122 121 00
Page 47: ... 47 IC Block Diagrams AD8183ARU Selector IC5241 BA6287F Motor Drive IC5501 IC5551 ...
Page 48: ... 48 CXA2101AQ RGB Matrix IC4101 IC Block Diagrams BA7078AF Selector IC6241 ...
Page 49: ... 49 CXD2064Q Digital Comb Filter IC2101 L3E01031 Level Shift IC3531 IC3561 IC Block Diagrams ...
Page 51: ... 51 ML60851 USB I F IC9801 M62393 D A IC2571 IC Block Diagrams ...
Page 52: ... 52 TA1318N AFC Detector IC6171 TB1274AF Video Decoder IC1101 IC Block Diagrams ...
Page 79: ...MD8 XU3100 79 46 44 44 46 44 44 Optical Parts List 46 57 56 46 46 ...
Page 80: ...MD8 XU3100 80 44 44 54 67 Red 68 Green 69 Blue 44 44 44 Optical Parts List ...
Page 81: ...MD8 XU3100 81 43 43 53 a Red 53 b Green 53 c Blue 61 44 44 46 43 46 53 Optical Parts List ...
Page 82: ...MD8 XU3100 82 52 a 52 45 45 45 45 52 Optical Parts List ...
Page 83: ...MD8 XU3100 83 Optical Parts List 58 70 63 71 57 60 65 59 64 66 51 55 62 ...
Page 84: ... MD8A Apr 2002 BB Printed in Japan SANYO Electric Co Ltd ...