7. PB LINE
OUT
Level Adjustment (Normal)
[Connection]
TP1 05
VRHS � OTP141
OCH2
EXT
[Adjustment
I
Check]
Measuring Point
Measuring Equipment
Condition
TP1 5 1 (CH 1 )
Oscilloscope
Playback
TP1 05 (EXT)
TP1 41 (GND)
Input Signal
I
Alignment Tape
(WR5-5CSP): For operation check,
color bar portion
ADJ. Location
ADJ.
I
Check Value
VR1 75
1 .00
±
0.02 Vp-p
Preparation:
• POWER switch: "PLAYER"
• Short pin @ and pin @ of J 1 005.
• An AV cord should be connected, and the video output
terminal should be terminated at 75
Q .
Adjusting
I
Checking method:
1 . Adjust with VR1 75 to 1 .00
±
0.02 Vp-p.
1 .00
±
0.02 Vp-p
8. PB LIN E
OUT
Level Adjustment (Hi8)
[Connection]
TP105
TP1 51
VR176 � OTP1 41
0CH2
[Adjustment
I
Check]
EXT
Measuring Point
Measuring Equipment
Condition
TP1 51 (CH 1 )
Oscilloscope
Playback
TP 1 05 (EXT)
TP1 41 (GND)
Input Signal
I
Alignment Tape
(WR5-8CSE): For operation check,
color bar portion
ADJ. Location
ADJ. / Check Value
VR1 76
1 .00 ± 0.02 Vp-p
Preparation :
• POWER switch: "PLAYER"
• Short pin @ and pin @ of J 1 005.
• An AV cord should be connected, and the video output
terminal should be terminated at 75
Q .
Adjusting
I
Checking method:
1 . Adjust with VR1 76 to 1 .00
±
0.02 Vp-p.
1 .00
±
0.02 Vp-p
- 5-1 8 -