1 5 . REC
AFM
Recording Current Check
[Connection]
[Adjustment
I
Check]
TP1 41
0
TP1 33
OCH2
0
EXT
Measuring Point
Measuring Equipment
Condition
TP1 33 (CH 1 )
Oscilloscope
Record
TP1 41 (GND)
MP type tape
Input Signal
I
Alignment Tape
Color bar (Audio input: No signal)
ADJ. Location
ADJ. / Check Value
400 ± 50 mVp-p
Preparation:
• POWER switch: "CAMERA"
• Stand-by switch: "STANDBY"
• Short pin ® , pin @ and pin @ of J1 005.
Adjusting
I
Checking method:
1 . Confirm that the oscillation voltage is 400 ± 50 mVp-p.
400 ± 50 mVp-p
1 6. REC
ATF
Recording Current Check
[Connection]
[Adjustment
I
Check]
TP1 41
0
CHl
0CH2
0
EXT
Measuring Point
Measuring Equipment
Condition
TP1 34 (CH 1 )
Oscilloscope
Record
TP1 41 (GND)
M P type tape
Input Signal
I
Alignment Tape
Color bar
ADJ. Location
ADJ.
I
Check Value
200 ± 20 mVp-p
Preparation:
• POWER switch: "CAMERA"
• Stand-by switch: "STANDBY"
• Short pin ® , pin @ and pin @ of J 1 005.
Adjusting
I
Checking method:
1 . Confirm that the oscillation voltage is 200
±
20 mVp-p.
j.-
1 0µ sec
-.j
- 5-22 -