10
Error messages
Cause and corresponding
Set up the parameter.
Error when the communication is executed. The parameter setting (host
name, capture port) has not been set.
➔
Check parameter setting (
+
p.90)
It has not been registered to PJ as a
group.
Error when Start Communication or Start real time capture is executed. The
IP address of the computer has not been registered.
➔
Register the IP address by using the web browser (
+
p.97)
Cannot be displayed as PJ is under
display.
Error when Start Communication or Start real time capture is executed. The
other capture, viewer or memory viewer function is now operating.
➔
Wait until the communication function is available.
Cannot connect to PJ.
Cannot establish the connection with the projector when the Start
communication is executed, Terminate Communication, Capture transfer,
Start real time capture or Terminate capture.
➔
Check connection of the network cable.
Cannot transfer data to PJ.
Cannot transfer the data to the projector when the Start Communication,
Terminate Communication, Capture transfer, Start real time capture or
Terminate capture is executed. The time-out period is 10 seconds.
➔
Check the connection of the network cable.
Cannot receive data from PJ.
Cannot receive the data from the projector when the Start
Communication, Terminate Communication, Capture transfer, Start real
time capture or Terminate capture is executed. The time-out period is 10
seconds.
➔
Check the connection of the network cable.
Other PC has authority.
Cannot complete "Network
Communication".
When executing the Terminate Communication, you cannot quit the
communication because other computer has an authority
Other PC has authority. Cannot
obtain authority.
Other computer has an authority.
Invalid port number
When the parameter is set, the reserved port number is specified.
➔
Check the parameter setting (
+
p.90)
PJ has not started Network
Communication. Close the window
and open it again.
The projector might have turned off during the communication.
➔
Check the projector power and re-execute "Start communication".
Error information
Error information
Summary of Contents for 1AV4U19B25500
Page 16: ...16 Chapter 1 About LAN functions ...
Page 64: ...64 Chapter 6 Basic setting and operation ...
Page 112: ...112 Chapter 8 Network capture functions ...
Page 132: ...132 Chapter 9 Network Viewer functions ...
Page 136: ...136 Chapter 10 Network Projector Windows Vista ...
Page 154: ...SO WIN KY7AC NETWORK OWNER S MANUAL FOR WINDOWS SANYO Electric Co Ltd ...