background image

System: 24KLS72  Indoor/Outdoor: KS2472/CL2472

Wall Mounted Low Ambient Air Conditioner

Power   

 

V/PH/Hz  

 

230/208/1/60

Circuit Ampacity
Fuse Size, Max.

Compressor

No. used
R.L. Amps  - L.R.
Crankcase Heater

Outdoor Unit

Fan type  
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps

Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size

Indoor Unit

Fan type  
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps

Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size

Refrigerant

Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max
Lift Difference, Max
Line Size
Line Size

Dimensions

Indoor Unit

Outdoor Unit

Weight

Net 
Shipping

Shipping Volume

Performance Data @ ARI Standard Conditions (230V)

Cooling

Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating

                  (A)                                               20

                    (A)                                               20

        General Data (at 230/208V)

1

                           (A)                               9.6/10.9 - 17.5

                     (W)                                                     20

  Propeller

18 - 1/8 - 1

DC Motor

                  (RPM)                                         8 - 850

             (W)                                              90 - 1

17

                           (Pints/H)                                    4.89

(BTU/H)        24,200 (4,100-24,200)

(BTU/H)                                14,800
(BTU/H)                                  9,400

(Uncrated)        11-23/32 x 41-15/16 x 8-19/32

             (W)             2,355/2,355 (280-2,355)

Aluminum Fin & Copper Pipe

Corrugated Plate - Inner Riff ed

       (in.)                                               3/8”

4.30

Split System Submittal Data

Electric Expansion Valve

Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:

Approval:
Date:
Construction:
Unit #:
Drawing #:

2 - 18.1

            (sq.ft.)                                                6.4

(lbs.)         26.5                                           119

                          (A)                     10.8/12.1(1.3-12.1)

(in. O.D. Discharge)                       1/4”

(in. O.D. Suction)                         5/8”

DC Rotary Inverter

                  (High)                                               600

                  (A)                                                   0.7

R410A

(in.)                                        H x W x D

(Crated)                 11-3/8 x 44-7/8 x 14-29/32

Indoor                                   Outdoor

(cu.ft.)        4.23                                           12.71

Indoor                                   Outdoor

(lbs.)         33.1                                        127.9

             (dB-A)                                              55

Cross Flow

3-11/16  33-9/32 - 1

3 & Auto

                  (RPM, High)                                 8 - 1250

             (W)                                             30 - 1

Aluminum Plate Fin & Copper Tube

Slit Plate - Inner Riff ed

       (in.)                                                9/32”

2 - 19.5

            (sq.ft.)                                                3.07

(HI/Med/Lo)                          600/541/482

                  (A)                                                   0.5

  (in.)                                              23/32”

             (Hi) (dB-A)                                                47

Flare

131

50

(Uncrated)            29-1/8 x 35-7/16 x 12-19/32

(Crated)             33-27/32 x 40-5/8 x 16-1/4

Reviews: