Reset the Battery information after replacing the battery installed in the UPS. The following actions will reset all battery information (such 
as expected battery lifetime, battery operating time, power outage count, etc.): If you have additional batteries, do so after replacing all 
the battery packs. 
 

 

Make sure the UPS is in the following state.   

 
 
 
 
 
 

 

Press 

  for 

3~4

  seconds and release it when the buzzer alarms. 

 
 
 
 
 
 
 
 
 
 

 

Promptly press the 

  (3 second or less) several times until the five LEDs enclosed by            are in the blinking pattern as shown 

in the figure.   

 
 
 
 
 
 
 
 
 
 

 

  Promptly press the 

  (3 second or less) several times until the four LEDs with                  are in the blinking pattern shown in the 

figure. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Press promptly 

Press promptly 

Reset  the  battery  information  after  replacing  the 

battery. If you do this incorrectly, the battery life warning 

will not display correctly. 

 

The    MAIN SW    on the back side is set to 

ON

※1

INV.ON/STAND BY green

and

OUTPUT green

are 

not blinking. 

※2

 

UPS is in user setting mode 

Buzzer: 

beep, beep

 

Either

BATT.LOW

or

25

is blinking or both

 

 

 

INPUT

Blinking

   

Off 

Blinking 

Indicator

 

1 

 

can  be  operated  either 

ON

  or 

OFF

  state. 

2.

If  blinking,  the

    Forced  Bypass 

 

switch  is  set  to 

Bypass

.Set  it  to 

Inverter

  and  operate  again.

 

 

 

POINT

 

Every  time  you  press 

  or

 

 

the  blinking  pattern  changes.

If  you  push  too  far  and  slip  through  the  LED  blinking  pattern   

you  want  to  select,  press  repeatedly  until  the  LED  blinking   

pattern  you  want  to  select  again  appear. 

 

POINT

 

 

Example

LED blinking pattern when set the setting value to 

reset 

 

 

 

 

Setting Value 

LED blinking 

pattern 

Details 

Do not reset 

●  ○  ○  ○ 

Do not reset 

Reset 

○  ●  ○  ○ 

Reset Battery Information 

Reset  the  battery  information  (expected  battery  lifetime, 

battery operating time, power outage count, battery life LED 

indication) after replacing the battery.

   

Initial Setting 

Summary of Contents for A11H Series

Page 1: ... in the table above is always occuring on the battery terminal so do not touch them with your hands or short circuit them There is a risk of electrick shock or injury Also for safety use insulation method such as attaching vinyl tape to the used battery pack connector To safely replace the battery pack please refer to the A11H insturction manual M0011840 B Ba at tt te er ry y R Re ep pl la ac ce e...

Page 2: ...ed that you do it in a short period of time because you will not be able to back up when an input abnormality such as a power outage occurs during replacement A11H stop For more information on stopping procedures please refer to A11H s Instruction Manual Stop the load equipment If the A11H U model is used as a UL Standard Product and CE Marking Conformity Product you may not be able to replace the...

Page 3: ...ge and charging of the battery Battery disintergrate during storage so please use as soon as possible Store the battery in a dry place where the temperature is low During storage please charge once at least every 6 months storage temperature 25 and before use Please charge with the UPS charger Refer to A11H Owner s Manual Charging the UPS 3 Battery Transportation and Handling As a rule avoid abnor...

Page 4: ...o be careful no to pinch your hands when dealing with battery packs The A11H302 battery pack has a scale at the top shown on page 1 When the scale is seen keep the bottom part supported with both hands and be careful not to drop it Remove by sliding in the direction of the arrow by holding two places of strongly Battery Cover Loosen the screw and slide the battery cover in the direction of the arr...

Page 5: ...ome off the battery cover For service personnel only Slide the switch to Bypass Pull out the battery pack out Disconnect the battery conn ector Attach the tape and insulate it For service personnel only Slide the switch to Bypass Disconnect the battery connector Attach the tape and insulate it Pull out the battery pack out Remove by sliding in the direction of the arrow by holding two places of st...

Page 6: ...y pack depends on the model Please see the size on page 1 If you have an additional battery module replace the battery after Insert the battery pack in the direction of the arrow Plug in the battery connector until you hear a click sound Plug in the battery connector until you hear a click sound The diagram shows the case of A11H202 The size of the battery pack depends on the model Please see the ...

Page 7: ... switch Forced Bypass is on the Inverter side the LED OUTPUT green and INV ON STAND BY green on the front panel are lit when the UPS is in operation Install the battery cover Fit the front cover When it is not used as a UL Standard When it is used as a UL Standard for service personnel When it is used as a UL Standard and CE Marking Conformity Product for service personnel ...

Page 8: ...is blinking Press for 1 second and check if INV ON STAND BY green turns on then proceed to step Caution For service personnel only Slide the switch to Inverter Insert the tabs into the slots and slide it down until you hear a click sound Secure it with the screws Attach and slide the front cover in the direction of the arrow until the claw hook Attach and slide the front covers in the direction of...

Page 9: ... the battery information after replacing the battery If you do this incorrectly the battery life warning will not display correctly The MAIN SW on the back side is set to ON 1 INV ON STAND BY green and OUTPUT green are not blinking 2 UPS is in user setting mode Buzzer beep beep Either BATT LOW or 25 is blinking or both INPUT Blinking Off Blinking Indicator 1 can be operated either ON or OFF state ...

Page 10: ...o normal operation After resetting the setting are automatically returned to Do not reset ress for 3 4 seconds and release it when the buzzer alarms If BATT LOW is still blinking the battery information is not reset correctly Please reset it again Caution Press 3 4 seconds and release it when the buzzer rings beep beep ...

Page 11: ...d on January 2015 the next replacement period is after four years and 6 months from the date of replacement 2019year 6month JUN 2019 Caution for Storage Battery replacement Label If the second row is already filled in write the replacement date in a memo and attached it in a visible place that is easy to see but will not be a hindrance to UPS intake exhaust fan 2019 JUN Please fill in with marker ...

Page 12: ...ent date using an indelible pen such as a permanent marker Average Ambient Operating Temperature Expected Battery Lifetime Battery Replacement Period 25 77 F 5 years 4 5 years 30 86 F 3 5 years 3 years 35 95 F 2 5 years 2 years 40 104 F 1 7 years 1 5 years Note The temperature may greatly affect the service life of the battery as shown in the table above To secure safe operation always replace the...

Reviews: