23
7
Service
7.1
Replacing Fan Motors and Blades
HAND PROTECTION REQUIRED!
Activities to be undertaken require finger and palm protection to prevent personal injuries.
To replace the fan motors:
①
Remove the outer Air Curtain Duct Cover and socket covers.
②
Unplug the fan motor harness and push through hole in plenum.
③
Detach fan motor mounting bracket from plenum and pull up to remove.