This unit is provided with the following SERVICE MODES so you can repair, examine and adjust easily.
To enter to the SERVICE MODE function, press and hold both buttons simultaneously on the main unit and on the remote
control for more than a the standard time in the appropriate condition. (See below chart.)
VOL. DOWN
(Minimum)
Initialization of factory TV data.
POWER ON
1
2 sec.
NOTE: If you set factory initialization, the memories are reset such
as the channel setting, and the POWER ON total hours.
Can be checked of the INITIAL DATA of MEMORY IC.
POWER ON
6
2 sec.
Refer to the "WHEN REPLACING EEPROM (MEMORY) IC".
VOL. DOWN
Check of the SUM DATA, POWER ON total hours and MICON
(Minimum)
VERSION on the screen.
Refer to the "WHEN REPLACING EEPROM (MEMORY) IC".
Display of the Adjustment MENU on the screen.
POWER ON
9
2 sec.
Refer to the "ELECTRICAL ADJUSTMENT" (On-Screen Display
Adjustment).
VOL. DOWN
Releasing of HOTEL MODE FUNCTION
(Minimum)
Refer to the "HOTEL MODE FUNCTION".
SERVICE MODE LIST
Set
Condition
Set Key
Remocon
Key
Standard
Time
Operations
TV mode
0
2 sec.
Releasing of V-CHIP PASSWORD.
VOL. DOWN
(Minimum)
VOL. DOWN
(Minimum)
POWER ON
8
2 sec.
VOL. DOWN
(Minimum)
POWER ON
MENU
2 sec.
C-1