WHEN REPLACING EEPROM (MEMORY) IC
C-2
CONFIRMATION OF CHECK SUM, POWER ON TOTAL HOURS AND MICON VERSION
Initial total of MEMORY IC, POWER ON total hours and MICON VERSIONcan be checked on the screen. Total hours are
displayed in 16 system of notation.
NOTE: If you set a factory initialization, the total hours is reset to "0".
Please refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding.
1. Turn on the POWER, and set to the ALL mode.
,
2. Set the VOLUME to minimum.
3. Press both VOL. DOWN button on the set and Channel button
(8)
on the remote control for more than 2 seconds.
4. After the confirmation of each check sum, turn off the power.
NOTE: The each item value might be different according to each set.
CHECK SUM : 6216
Initial setting data check sum.
LCD PWR ON : 0000
POWER ON total hours.
HDMI data check sum
HDMI SUM : 3500
+ (16 x tens digit value)
HDMI data check sum.
HDMI SUM : 3500
+ (16 x tens digit value)
Main Micon check Version.
DTV : CA6FI111411
+ (ones digit value)
EEPROM check Version.
EEPROM : K3FR03WM00
Parameter check Picture Quality.
QUALITY :
@@@@.@@ (@@@@@@ @@:@@:@@)
Parameter check Picture Size.
SCALING :
@@@@.@@ (@@@@@@ @@:@@:@@)
CONFIRMATION OF INITIAL DATA
FIG. 1
CONFIRMATION OF INITIAL DATA
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken
to ensure correct data settings while making reference to INITIAL SETTING TABLE (Attached "INITIAL DATA").
1. Turn on the POWER, and set to the ALL mode.
2. Set the VOLUME to minimum.
3. Press both VOL. DOWN button on the set and Channel button
(6)
on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 2.
NOTE: No need to set data other position than 0200~0F79.
ADDRESS
DATA
INIT :
0001 0086
DTV : CA6FI11141
EEPROM : K3FR03WM00
4. ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the ADDRESS
until required ADDRESS to be changed is reached.
5. Press VOL.UP/DOWN button to select DATA. When DATA is selected, it will "blink".
6. Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
7. Pressing VOL.UP/DOWN button will take you back to ADDRESS for further selection if necessary.
8. Repeat steps 4 to 6 until all data has been checked.
FIG. 2
8. Repeat steps 4 to 6 until all data has been checked.
9. When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
10. Turn on the Power.
11. Set the VOLUME to minimum.
12. Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
13. After the finishing of the initializing of shipping, the unit will turn off automatically.
The unit will now have the correct DATA for the new MEMORY IC.