RECORD SET
3
84
English
SETTINGS
z
The period for “T-1” through “T-4” as set in step 9
changes to that of “TIME PERIOD A” or “TIME PERIOD
B” on P.57.
z
When time period is unset, T-1 settings are enabled
and T-2 through T-4 are disabled.
z
The sensitivity level can be checked using the setting
screen. When motion is detected, the sensor color
changes from green to red, and a buzzer is sounded.
If detection is too sensitive, an alarm can be triggered
even by slight changes in lighting; accordingly, the
sensitivity level should be set to match the camera
location.
1
Press the [MENU] button and turn the
jog dial to select “2. RECORD SET”, and
then turn the shuttle dial.
The <RECORD SET> screen is displayed.
2
Turn the jog dial to select “8. ALARM
OPERATION SET”, and then turn the
shuttle dial clockwise.
The <ALARM OPERATION SET> screen is displayed with
the cursor positioned on “ALARM RETRIGGER”.
3
Turn the shuttle dial clockwise.
“OFF” flashes in the “ALARM RETRIGGER” field.
4
Turn the jog dial to set the alarm trigger
to “ON”, and then turn the shuttle dial
clockwise.
The cursor moves to “MAIN MON. DISPLAY”.
[Settings] (
indicates default setting)
1
Turn the jog dial to select “MAIN MON.
DISPLAY”, and then turn the shuttle dial
clockwise.
“FULL” starts to flash for “MAIN MON. DISPLAY”.
[Settings] (
indicates default setting)
Setting alarm operation and display
MENU
<ALARM OPERATION SET>
ALARM RETRIGGER : OFF
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : OFF
Setting
Description
OFF
Even if a new alarm is received on the same channel
during alarm recording, the duration is not extended.
ON
If a new alarm is received on the same channel during
alarm recording, the duration is extended and both
alarms are treated as one. (Example: Input in the alarm
sequence A
→
C) However, if the new alarm is on a
different channel, the alarms are treated separately.
(Example: Input in the alarm sequence A
→
B
→
C)
Setting alarm display
Setting
Description
FULL
When an alarm is detected, the video on the
channel containing the alarm is displayed in full
screen format on the main monitor.
9
When an alarm is detected, a multi-9 screen
display is presented on the main monitor.
16
When an alarm is detected, a multi-16 screen
display is presented on the main monitor. (This can
only be set on the DSR-3716P.)
NC
The main monitor’s display does not change when
an alarm is detected.
CH1
CH2
Alarm
Alarm
Alarm Recording A
Example:
Alarm
Alarm Recording C
Alarm Recording B
<ALARM OPERATION SET>
ALARM RETRIGGER : ON
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : OFF