RECORD SET
2
English
101
z
When only one camera is connected, recording is
performed at 25 FPS even if 50 FPS is set.
z
With 50 FPS set, when two or more cameras are
connected and “ALARM INTERLEAVE” is set to “ALL” , the
actual recording rate is roughly the recording rate divided
by the number of cameras. (Example: When 4 cameras are
connected and the recording rate setting is 50 FPS, the
actual recording rate is 12.5 FPS.) It varies depending on
the setting of “ALARM INTERLEAVE” and the number of
alarms.
14
Turn the shuttle dial clockwise.
“20SEC” flashes.
15
Turn the jog dial to select the
“DURATION” setting and then turn the
shuttle dial clockwise.
The cursor moves to “PRE-ALARM RECORDING”.
[Settings] (
indicates default setting)
16
Press the [EXIT/OSD] button.
The setting is completed and the display returns to the normal
screen.
“ALARM” appears in the operation display.
When an alarm occurs, the number of alarms is displayed.
z
When an additional alarm is received on another channel
while alarm recording is in progress, the number of alarm
increments; thus they are counted as two alarms.
However, when an additional alarm is received on the
same channel, the both alarms are treated as one (e.g. an
additional alarm is received on CH1 while the channel is
being used for alarm recording.)
Setting
Description
5SEC, 10SEC,
20SEC,
40SEC, 1MIN, 2MIN, 3MIN,
4MIN, 5MIN, 10MIN, 15MIN
Records for the set duration for
each alarm.
CC
Records while an alarm is
activated.
Recording continues for five
seconds even if entry is less than
five seconds.
<ALARM REC MODE SET>
ALARM RECORDING : ENABLED
PICTURE QUALITY : ENHANCED
PICTURE QUALITY SET ->
AUDIO RECORDING : ON
ALARM INTERLEAVE : ONLY
REC RATE:A12.5FPS, DURATION: 20SEC
PRE-ALARM RECORDING : ***
REC RATE: ***** FPS, DURATION: *****
ALARM TRIGGER : ALARM
MOTION SENSOR ->
<ALARM REC MODE SET>
ALARM RECORDING : ENABLED
PICTURE QUALITY : ENHANCED
PICTURE QUALITY SET ->
AUDIO RECORDING : ON
ALARM INTERLEAVE : ONLY
REC RATE:A12.5FPS, DURATION: 20SEC
PRE-ALARM RECORDING : OFF
REC RATE: ***** FPS, DURATION: *****
ALARM TRIGGER : ALARM
MOTION SENSOR ->
01-01-07 00:00:00 REC REPEAT EN A ALARM 0000001
02
Number of alarms
“ALARM” display