- 23 -
HEC-DR5000
(GENERAL)
Replacement Procedure
(4) Replacement of Reclining Motor
1, Take off the arm rest (left). Photo-1
2, Take off the arm rest (right). Photo-5
3, Disconnect each cord processing and cords.
4, Lay down the massager with its left side
facing downward. Photo-8
5, Each reclining motor (set) is fixed at two
places on both ends. Therefore, remove
E rings on both ends and pull out fixing pins.
Photo-9
(5) Replacement of Power Switch
and Current Fuse
1, Take off the arm rest (right). Photo-5
2, Remove each cord processing and
disconnect the cords.
3, Remove two case (switch box) set screws
and take off the case (switch box).
Photo-10
4, Open a fuse case of current fuses and take
out a current fuse. Photo-11
5, Remove two switch holder set screws and
take off a switch holder.
Photo-11
6, Remove a switch fixing screw and take off
the POWER switch. Photo-11
Photo-8
Switch holder set screws
Case set screws
POWER switch
E rings & fixing pins
Photo-9
Reclining motor (foot rest)
Reclining motor (foot rest)
Reclining motor (back rest)
Connector (sensor)
Connector (remote control)
Reclining motor (back rest)
Photo-10
Photo-11
E rings & fixing pins
Case (switch box)
Current fuse
Power cord