- 27 -
HEC-DR5000
(GENERAL)
Replacement Procedure
(10) Replacement of PCB (strength pulse)
1, Disconnect the connector CN931 of the PCB
(strength pulse). Photo-23
2, Remove one PCB (strength pulse) set screw
and take off the PCB (strength pulse).
Photo-23
(11) Replacement of Motor (strength)
1, Remove each cord processing.
2, Remove two stay (under the motor (strength))
set screws. Photo-24
3, Disconnect the belt (strength). Photo-23
4, Remove two motor (strength) set screws and
take off the motor (strength) and the stay
(under the motor (strength)). Photo-23, 24
5, Remove two motor (strength) set screws and
take off the motor (strength).
* Exercise care so as not to adhere grease to
the driving portions such as belt
(Failure to observe this precaution may lead
to malfunction due to slippage).
(12) Replacement of PCB (Massage)
1, Disconnect five PCB (massage) connectors.
Photo-25
2, Remove two PCB (massage) set screws and
take off the PCB (massage). Photo-25
(13) Replacement of Motor (Massage)
1, Remove each cord processing.
2, Disconnect the belt (massage). Photo-25
3, Remove two motor (massage) set screws.
Photo-25
4, Remove two stay (under the motor (massage))
set screws and take off the motor (massage).
and the stay (under the motor (massage)).
Photo-26
5, Remove one motor (massage) set screw and take
off the motor (massage). Photo-26
* Exercise care so as not to adhere grease to
the driving portions such as belt (Failure to
observe this precaution may lead to
malfunction due to slippage).
Motor set screws
Motor (strength)
Belt(strength)
Photo-23
Photo-24
Stay set screw
Stay (under the Motor (strength))
Motor (strength)
PCB (massage pulse)
PCB set screw
Motor set screws
Motor (massage)
Belt (massage)
Photo-25
Photo-26
Stay set screw
Motor set screw
Stay (under the massage motor)
Motor (massage)
PCB set screw
PCB (strength pulse)