background image

General Installation Manual 

© Mar 2009, Sanyo Electric Co., Ltd.  All Rights Reserved   3/23/09 

 

 

5

 
 

 

 
 
 
 
 
 
 

Cup washer (Terminal cup) 
(Stainless steel or *brass) 

Figure 3.2 (Method 1) 
Grounding method  
using self-tapping screw 
 

Note: Use the smaller ground 
holes illustrated in Figure
3.1.

 

Frame (Longer side)

Ground wire (#12AWG) 
(wound around the screw) 

Flat washer (Stainless steel) 

Spring washer (Stainless steel) 

Self-tapping screw (Stainless steel) 
  #10-32  

Grounding hole  
(0.165’‘ diameter (4.2 mm) ) 

Glass

Length  
(not less than 0.47’‘(12 mm)  
not more than 0.78’‘(20 mm))  

Backsheet 

*Flat washer (Stainless steel) 

 

*

If using a brass cup washer, a flat washer must be inserted between the cup washer and 

module frame, and the flat washer diameter must be greater than the cup washer diameter. 

*

If using a brass cup washer, a flat washer must be inserted between the cup washer and 

module frame, and the flat washer diameter must be greater than the cup washer diameter. 

Cup washer (Terminal cup) 
(Stainless steel or *brass) 

Star washer (Stainless steel)

Flat washer (Stainless steel)

Flat washer (Stainless steel) 

Spring washer (Stainless steel) 

Bolt (Stainless steel) 
  #8, #10, M5 

Grounding hole 
 0.205’‘ diameter 
  (5.2 mm)) 

Length  
(not less than 0.63’‘(16 mm)  
 not more than 0.78’‘(20 mm)) 

Frame (Longer side) 

Nut (Stainless steel)

Figure 3.3  (Method 2) 
Grounding method  
using bolt and nut

  

 

Note: Use the larger ground 
holes illustrated in Figure 
3.1.

 

 

Ground wire (#12AWG) 
(wound around the bolt) 

Glass

Backsheet 

*Flat washer (Stainless steel) 

Summary of Contents for HIT Power 215N

Page 1: ...with a dense opaque material such as a cardboard box during installation and handling of the modules Work only in dry conditions with dry modules and dry tools Do not stand or step on a module Do not puncture cut scratch ordamage the back sheet of a module Back sheet damage will void a module s Limited Warranty and may cause fire Never use modules with a damaged back sheet Do not allow children an...

Page 2: ...e frame If other mounting means are employed this may effect the temperature of the panel SANYO recommends the installation method and mounting profile shown in Figure 1 A module should be attached on a mount or support structure rail by metal clamps The metal clamp must fulfill the following specifications Size not less than 1 5 38 mm width Thickness not less than 0 12 3 mm Material aluminum allo...

Page 3: ...upon screw threads two or more screws or two full threads of a single screw must engage the metal All the washers illustrated in Figures 3 2 and 3 3 are required as part of the grounding connection Great care should be exercised to ensure that corrosion caused by the grounding means be avoided Corrosion can increase the resistance of the grounding connection on the module or can even cause the gro...

Page 4: ...llow the applicable codes for outdoor installation of wires in conduits Verify that all fittings are properly installed to protect wires against damage and prevent moisture intrusion DIODES Bypass Diodes When modules in series strings are partially shaded it may cause reverse voltage across cells or modules because the current from other cells in the same series is forced to flow through the shade...

Page 5: ...ted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter Cup washer Terminal cup Stainless steel or brass Star washer Stainless steel Flat washer Stainless steel Flat...

Page 6: ...aximum System Voltage Voc 600 600 600 600 Factory Installed Bypass Diodes 3 3 3 3 Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds Electrical Specifications 16 35 3 1580 62 2 798 31 4 46 1 8 SPECIFICATIONS Section A A Figure 2 Dimensions Dimensions All HIT Power N Models HIP xxxNKHA5 Label Note A module should be installed on a mounting structure ra...