2 Adjustment
Equipments
Multimeter or oscillo
scope
VG-849
CA-21
0
USB
storage device
DVD ( HDMI 1.4
supported
) or equipments with the same functions
3 Adjustment
Processes
3.1 Power voltage
checking
According to the wiring diagram specified by “Product Specification”, connect power board
assembly, data processing assembly, IR/Key board assembly, backlight board assembly correctly,
supply with power, press button
to power on the TV set.
Make sure the voltages of socket X601 each pin on the main board are correct.
Voltage value
and range are listed as
Table 1:
Table 1 Voltage of X601 each pin
X601
Pin1,2
3,4
5,6 7,8 9 10 11 12 13
Voltage 24V±5% 0 12
V±5% 0
≤
5.2V
5 V±5%
5 V±5%
≤
5.2 V
≤
5.2 V
Function AMP_PWR GND
12V
GND
PWR_SW
Main
5V
+5V
STB
BL_PWM BL_ON