LENS MOTOR LEAD
CONNECTOR “ K16B”
(D)
(D)
(D)
(D)
C
LENS MOTOR
❋
Figure shown inside of the cabinet.
REMOVE THE LENS. (See figure-4)
1. Remove the connector “K16B” of the
circuit board.
2. Loosen the A, B, C wire holder and
remove the lens motor lead.
3. Remove screws D (4 screws) which
fastens the lens and remove the lens.
●
IN CASE OF MODEL WITH LENS
B
ATTACHED DRIVER
Fig-5
LENS MOUNTING BRACKET
LENS MOTOR LEAD
CONNECTOR “K16B”
(D)
(D)
(D)
(D)
B
A
LENS MOTOR
Fig-4
This part wiring should
not be tightened.
C
A
INSTALL THE LENS. (See figure-4,5)
3
1. Remove protective caps (front
and back ) on the lens.
2. Mount the lens at the lens
mounting bracket with screws
(4 screws) included with the
lens. Use the driver included
with the lens to fasten the
screws . (After using, save it for
latter use.) (See figure-5)
3. Connect the lens motor lead to
the connector “K16B” of the
circuit board. (See figure-4)
4. Fasten the lens motor lead at
the A, B, C points with wire
holder.
(See figure-4)