The Safest Ultra-Low Freezers 
for Long-Term Storage of Ultra-
Critical Biologicals

The SANYO Twin Guard Series

 satisfies 

the industry demand for safe, long-
term storage for the most high-valued 
materials. Two independent refrigeration 
systems, combined with optional liquid 
nitrogen or liquid CO

2

 back-up systems, 

offer a circle of protection unmatched in 
the marketplace. Developed for use with 
conventional inventory racks and boxes, 
the Twin Guard Series

 is ideal for stor-

age of sensitive stem cells, embryos, 
cell lines, and other rare specimens.

Twin Guard Series™ -86 Dual°Cool 
Refrigeration System

The Twin Guard Series

 Ultra-Low Freez-

er avoids conventional cascade refrigera-
tion technology by using two completely 
independent one-compressor, autocas-
cade cooling systems, each capable of 
maintaining ultra-low temperatures.

• 

Each refrigeration circuit includes a 
closed-loop cold-wall evaporator con-
figured in parallel to the other.

• 

Independent evaporators and cooling 
fans assure back up status at all times, 
eliminating system failure due to 
sub-component failure in conventional 
cascade systems configured of mutu-
ally dependent high- and low-stage 
systems.

Independent systems efficient ultra-low cooling is 
achieved through two independent evaporator circuits 
surrounding the interior chamber.

Ultra-Critical Installations and Applications Overview

Application

Justification

Benefit

Stem Cells, Cord Blood, T-Cells, Engineered Tissue, 

Organ/Tissue, Vaccines, Bone Marrow, Hybridomas,  

Lymphocytes, Cancer Cells, Clinical Specimens,  

Fibroblasts, Ova, Sperm 

Highly sensitive to temperature fluctuations or 

uneven storage temperatures at different positions 

within the interior chamber.

Enhanced temperature uniformity, top-to-bottom, 

front-to-back, assures sample stability at all  

inventory locations.

BSL-3/4 or Highly Secured Labs

Restricted access to the contained laboratory  

limits serviceability.

Twin Guard Series

 extends critical time necessary  

to react in the event of mechanical failure.

• 

In the unlikely event of a compressor 
failure in one system, the remaining 
system will automatically maintain a 
minimum of -65°C for an indefinite 
period. 

• 

In the event of a facility power failure 
with optional CO

2

 or LN

2

 backup sys-

tem installed, the freezer will maintain 
-65°C storage temperature for up to 
eight hours (CO

2

 backup system) and 

-65°C storage temperature for up to  
15 hours (LN

2

 backup system).

• 

A unique EcoMode

 deploys both sys-

tems in overlapping cycles to maintain 
-86°C and to reduce energy consump-
tion by as much as 15%.

• 

Evaporator coils embedded in the pat-
ented, high-tech, SANYO V.I.P. PLUS

 

vacuum-insulated thin-wall cabinet are 
strategically oriented to deliver the 
best temperature uniformity at all shelf 
levels, top-to-bottom and front-to-back.

• 

New SANYO-designed Cool Safe

 

refrigeration compressors feature inno-
vative refrigerant feedback processes 
to reduce compressor temperature, 
thereby extending compressor life and 
minimizing heat output. 

The SANYO MDF-500VXC and MDF-U700VXC Twin Guard Series™ ultra-low freezers are designed for -86°C storage of high-value biologicals. 
Ideal for critical material storage in repositories, highly secure BSL3/4 labs, hospitals, clinics and medical research facilities. The Twin Guard 
Series

 introduces the concept of dual, independent, auto cascade refrigeration systems contained within a single cabinet.

Summary of Contents for MDF-U500VXC

Page 1: ...es www sanyobiomedical com GREEN product Features SANYO 86 Dual Cool ultra low freezer is designed for 86 C storage of high value biologicals Includes integrated LCD performance monitor and digital controller for comprehensive system management 86 C Ultra Low Freezers MDF U500VXC MDF U700VXC ...

Page 2: ...e Energy SAVE Air Filter VIP Plus Vacuum Insulation Panel VIP Filterless Design Insulated Inner Doors ICD Digital Display Remote Alarm CPU and Touch Pad Free VIP Vacuum Insulation Panel VIP Quiet Reliable Compressor Cascade Cooling System vice ic tem able y Energy SAVE Air Filter VIP Plus Vacuum Insulation Panel VIP Filterless Design Insulated Inner Doors ICD Digital Display Remote Alarm CPU and T...

Page 3: ... temperature fluctuations or uneven storage temperatures at different positions within the interior chamber Enhanced temperature uniformity top to bottom front to back assures sample stability at all inventory locations BSL 3 4 or Highly Secured Labs Restricted access to the contained laboratory limits serviceability Twin Guard Series extends critical time necessary to react in the event of mechan...

Page 4: ...on Cabinet design attributes include high strength lockable door latches and doors latchable inner doors adjustable shelves locking casters and seismic restraints to simplify operation installation and to satisfy local codes Compliant to International Standards Assures quality standards safety and performance criteria are met or exceeded Essential for compliance with LEEDs RoHS OSHA other third pa...

Page 5: ...nally lower HVAC loads SANYO is conscious of the need to protect our environment and conserve energy As a corporate pioneer in life science laboratory equipment and appliances and as a global source of solutions ranging from energy manage ment to solar power and alternative energies SANYO remains committed to providing the best possible labora tory equipment for research and clinical needs Uniform...

Page 6: ...p to bottom uniformity Maintains most repeatable cycling wave form for the strictest of GMP applications B 86 C A System A ON Back Up for System B Maintains minimum 65 C reserve temperature B 65 C A System B ON Back Up for System A Maintains minimum 65 C reserve temperature B 65 C A The SANYO Twin Guard Series Freezer can be set for Normal or EcoMode operation EcoMode establishes an overlapping cy...

Page 7: ...l operation and Twin Guard Series backup Reduced Power Consumption The SANYO Twin Guard Series Freezer can be set for Normal or EcoMode operation depending on ambient tem perature and load EcoMode is recom mended for 90 95 of applications Although both refrigeration systems are completely independent EcoMode establishes an overlapping cycle to significantly reduce energy consump tion while optimiz...

Page 8: ...t puts and performance at a glance Multi point data logging offers a graphical display for temperature verification at a glance Precise logic systems control and adjust to temperature setpoints and alarm parameters Setpoint alarm and programmable inputs are established through pop up menus and function keys Logged parameters can be exported to remote databases off site alarm or data capture system...

Page 9: ...failure Solid Tone No Auto Return Touch key is not pressed for 90 minutes Reverts to chamber temperature display None No Door Alarm Door open Notification of error on graphical display Solid tone sounds after 2 minutes Yes New extended range is important for GxP applications to reduce potential incident event reporting The integrated microprocessor control aggregates information from the entire sy...

Page 10: ...ty Inner door latches are standard 7 New air cooled Super Condenser energy transfer technology maintains optimum condenser air flow and eliminates the need for an air filter or periodic cleaning and maintenance required by other manufacturers 8 High impact recessed casters and leveling feet simplify installation 9 Seismic restraints secure cabinet to building superstructure to meet local codes 10 ...

Page 11: ...YO ergonomic design features a high security Easy In Easy Out door latch designed for simplicity and safety Also allows for one handed operation 2 Barrier Film VIP Plus Interior Rigid foamed polyurethane 1 12 4 A vacuum relief valve is mounted in the left wall 17 16 ...

Page 12: ...ion when required RoHS Compliance In 2006 RoHS Restric tion of Hazardous Sub stances legislation EU Directive 2003 95 EU became effective RoHS relates to the restriction of hazardous substances and reductions in environmental pollution Through RoHS legislation the EU and other participating countries are banning toxic substances in electrical equipment such as lead cadmium mercury chro mium 6 PBB ...

Page 13: ...ounts on the cabinet door and is programmable to capture and store non corruptible data points for download ing to an independent data management system to meet criteria outlined in U S FDA21CFR Part II directives An inde pendent probe is placed in the interior chamber Inventory Rack Systems SANYO freezers are available with a variety of inventory racks to meet specific applications Freezers can b...

Page 14: ...3 locations Vacuum Release Port Standard Manual Refrigeration System Refrigeration Technique SANYO 86 Dual Cool independent redundant cooling systems with automatic switchover Compressors Per system Single hermetically sealed 1100W SANYO Cool Safe compressor air cooled Refrigerant Environmentally safe HFC refrigerant Air Exchange Dual condenser fans with particulate trap no filters are required Cy...

Page 15: ...15 Dimensional Drawings MDF U500VXC MDF U700VXC 34 3 870 21 0 533 ...

Page 16: ... installation qualification operational qualification performance qualification calibration and temperature mapping SANYO Connect SANYO s customer driven biomedi cal service program guarantees local attention from qualified SANYO service representatives whenever and wher ever you need it New Unit Installation and Training Preventative Maintenance Warranty and Non Warranty Repairs Calibration Valid...

Reviews: