DISPLAY SET SETTINGS
TITLE setting (default setting: DOWN)
A title such as the setup location can be set for each camera, and the position for displaying this title on the monitor screen can also
be changed.
Example: To assign a title of “HALL-1F” to camera 3 and set the display position to the top of
the monitor
Press the MENU button.
The MAIN MENU screen will be displayed.
Use the cursor button to select
“DISPLAY SET” and then press the
NEXT button.
The DISPLAY SET screen will be
displayed.
Use the cursor button to select
TITLE “DOWN”.
Use the setting buttons to select
“UP”, and then press the NEXT
button.
The normal monitoring screen will be
displayed and the title will appear at the top
of the screen.
MENU
1
(MAIN MENU)
1 LANGUAGE ¤
2 CLOCK SET ¤
3 DISPLAY SET ¤
4 VCR SET ¤
5 ALARM SET ¤
6 SECURITY SET ¤
7 CONTROL SET ¤
8 ALARM DATA ¤
(*:NEXT)
NEXT
2
(DISPLAY SET)
TITLE DOWN ¤
MULTI SCREEN NORMAL
SEQUENCE 1 S
MASK OFF
MAIN†SPOT1 OFF
DIGITAL CONNECTION OFF
COLOR LEVEL AUTO
(*:NEXT)
3
(DISPLAY SET)
TITLE DOWN ¤
MULTI SCREEN NORMAL
SEQUENCE 1 S
NEXT
+
–
4
(DISPLAY SET)
TITLE UP ¤
MULTI SCREEN NORMAL
SEQUENCE 1 S
CAMERA NO.01 --------01
Press camera select button 3.
The images from camera 3 will be
displayed on the monitor, and the cursor
will appear at the default title setting
position.
Use the setting buttons to display
“H”, and then press the cursor
button.
If the cursor button is pressed to the right,
the cursor will move to the right. Use this
procedure to enter “HALL-1F”.
3
5
CAMERA NO.03 --------03
+
–
6
If the title is to be altered, use the cursor buttons to
bring the cursor to the item that is to be changed and
select a setting button.
Note: Characters that can be displayed in a title
•
Alphabetic characters (A – Z)
•
Numerals (0 – 9)
•
Symbols (–, :, ., /, *, _<blank space>)
Note: To change the title display position, press the
BACK button and then re-select “UP” or “DOWN”
for the TITLE setting.
CAMERA NO.03 H-------03
CAMERA NO.03 HALL-1F-03
Press the BACK button.
The setting will then be completed and the
display will return to the DISPLAY SET
screen.
Press the BACK button once more to
return to the MAIN MENU screen.
DISPLAY SET-1
BACK
7
DISPLAY SET-1
– 40 –
English