PLC-ET30L Expand Serial Command Functional Specifications
26/62
8.6.7 CF_SYSTEM Command
Command
“CF_SYSTEM_%1” [CR]
%1
Input is
PC Analog
“VGA1” --------------------------- Select VGA1
“VGA2” --------------------------- Select VGA2
:
:
“XGA1” --------------------------- Select XGA1
:
:
“WXGA3” --------------------- Select WXGA3
“1080I” ------------------------ Select 1080i
“1035I” ------------------------ Select 1035i
“720p” ------------------------- Select 720p
“575p” ------------------------- Select 575p
“480p” ------------------------- Select 480p
“575I” -------------------------- Select 575i
“480I” -------------------------- Select 480i
“MODE1 - 10” --------------- Select MODE1 – MODE10
“EXT11 - 60” ----------------- Select Ex Mode11-60
* EXT1-10 is not set.
Input is
PC
Digital/AV
HDCP
“D-XGA1” --------------------- Select D-XGA1
:
:
“D-WXGA3”------------------- Select D-WXGA3
“D-1080I” --------------------- Select D-1080i
“D-1035I” --------------------- Select D-1035i
“D-720p” ----------------------- Select D-720p
“D-575p” ----------------------- Select D-575p
“D-480p” ----------------------- Select D-480p
Input is
Y,Pb/Cb,Pr/Cr
“AUTO” -------------------------- Select System “Auto”
“1080I” --------------------------- Select 1080i
“1035I” -------------------------- Select 1035i
“720P” --------------------------- Select 720p
“575P” --------------------------- Select 575p
“480P” --------------------------- Select 480p
“575I” ---------------------------- Select 575i
“480I” ---------------------------- Select 480i
Input is
Video / S-Video
“AUTO” -------------------------- Select System “Auto”
“NTSC” -------------------------- Select NTSC
“NTSC443” --------------------- Select NTSC4.43
“PAL” ----------------------------- Select PAL
“SECAM” ----------------------- Select SECAM
“PAL-M” ------------------------- Select PAL-M
“PAL-N” ------------------------- Select PAL-N
Details
Select System of currently selected Input
(Available only in the normal Power ON status)
When selected input does not include specified %1, error code “101” [CR] is
returned and it is not executed.
When Input No is 4, error code “101” [CR] is returned and it is not executed.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]