PLC-WXU10
23
Fail to light up
Refer to LED
indicator and follow
indicative actions
Replace
Lamp Module
Replace
Power board
Replace
Ballast
Replace
Mainboard
OK
OK
OK
OK
OK
NG
NG
NG
NG
NG
Check
Mainboard
Check Ballast
Check
Lamp life
Check LED
indication
Check Power board
380V output
Replace
Optical Engine
NG
Check CW
Rotation while power on
No Volume
Replace
Speaker
Replace
Mainboard
NG
NG
Ok
Check
Mainboard
Check
Speaker
Summary of Contents for PLC-WXU10B
Page 7: ...PLC WXU10 4 1 3 PLC WXU10 System Block Diagram ...
Page 17: ...PLC WXU10 14 Step Figure Description 9 Remove the screws as shown 10 Remove the housing mylar ...
Page 40: ...PLC WXU10 37 6 1 Mechanical Drawing M15 mylar 2 M12 ...
Page 41: ...PLC WXU10 38 6 2 Other drawing ...
Page 42: ...PLC WXU10 39 Projection Lens Assy L02 W07 ...
Page 43: ...PLC WXU10 40 W08 is the UV lens which is used to detect the temperature of panel W08 ...
Page 51: ......