- 5 -
■
Curcuit Protections
Fuse
A fuse is located inside of the projector. When the POWER indicator
is not lightning, the fuse may be opened. Check the fuse as following
steps.
The fuse should be used with the following type;
How to replace the fuse
1. The fuse is placed on the line filter board under the main board.
Remove the cabinet top and main board. (Refer to Fig.)
. Take the fuse off, and replace the new one with the specified type.
This projector provides the following circuit protections to operate in safety. If the abnormality occurs inside the projector, it will
automatically turn off by operating one of the following protection circuits.
Fuse Part No.: 323 025 1204
tYPE 8A 250V FUSE
LIttLE FUSE INC. tYPE 215008
Remove the 3 screws and remove the line filter board
Fuse (F601)
Line filter board
Summary of Contents for PLC-XE50