PLC-XTC50AL Expand Serial Command Functional Specifications
32/76
8.7.7 CF_VSCALE Command
Command
“CF_VSCALE_%1” [CR]
%1
“032” ---------------------- +32
“031” ---------------------- +31
:
“002” ---------------------- +2
“001” ---------------------- +1
“000” ---------------------- ±0
“
‐
01” ---------------------
‐
1
“
‐
02” ---------------------
‐
2
:
“
‐
31” ---------------------
‐
31
“
‐
32” ---------------------
‐
32
“UP” --------------------- Increment setting value of Vscale by 1
“DN” --------------------- Decrement setting value of Vscale by 1
Details
Set Vscale (Available only in the normal Power ON status)
* When selected screen mode is not “Custom”, error code “101” [CR] is returned
and it is not executed.
* Error Code “101” [CR] is returned for no signal.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.7.8 CF_VPOS Command
Command
“CF_VPOS_%1” [CR]
%1
“015” --------------------- +15
“014” --------------------- +14
:
“002” --------------------- +2
“001” --------------------- +1
“000” --------------------- ±0
“
‐
01” ---------------------
‐
1
“
‐
02” ---------------------
‐
2
:
“
‐
14” ---------------------
‐
14
“
‐
15” ---------------------
‐
15
“UP” --------------------- Increment setting value of Vposition by 1
“DN” --------------------- Decrement setting value of Vposition by 1
Details
Set V Position (Available only in the normal Power ON status)
* When selected screen mode is not “Custom”, error code “101” [CR] is returned
and it is not executed.
* Error Code “101” [CR] is returned for no signal.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]