PLC-XTC50AL Expand Serial Command Functional Specifications
34/76
8.8 Lamp Command
8.8.1 CF_LAMPMODE Command
Command
“CF_LAMPMODE_%1” [CR]
%1
“AUTO1” ------------- Set lamp status to Auto1 mode
“AUTO2” ------------- Set lamp status to Auto2 mode
“HIGH” --------------- Set lamp status to High mode
“NORMAL” ---------- Set Lamp status to Normal mode
“ECO1” --------------- Set Lamp status to Eco1 mode
“ECO2” --------------- Set Lamp status to Eco2 mode
“UP” ------------------ Select lamp control forward direction
“DN” ----------------- Select lamp control backward direction
Details
Select Lamp control (Available only in the normal Power ON status)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.8.2 CF_LAMPCONTRL Command
Command “CF_LAMPCONTROL_%1” [CR]
%1
“LAMP1” --------------------------- Set lamp mode to Lamp1
“LAMP2” --------------------------- Set lamp mode to Lamp2
“CHANGE”------------------------- Set lamp mode to Lamp1/2
Details
Select Lamp mode. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.8.3 CF_LAMPLIFECONTRL Command
Command “CF_LAMPLIFECONTROL_%1” [CR]
%1
“MODE1” --------------------------- Set lamp life control to Mode1
“MODE2” --------------------------- Set lamp life control to Mode2
Details
Select Lamp life control (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.8.4 CF_LAMPCHGTIM Command
Command “CF_LAMPCHGTIM_%1” [CR]
%1
“ON” --------------------------- Set Timer to On
“OFF” -------------------------- Set Timer to Off
Details
Select Timer for Lamp1/2 of Lamp mode.
(Valid only when in the normal Power ON status.)
*When Lamp mode is not set to Lamp1/2, error code “101” is returned.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]