PLC-XTC50AL Expand Serial Command Functional Specifications
50/76
9.5 PC Adjust Status Read Command
9.5.1 CR_FSYNC Command
Command
“CR_FSYNC” [CR]
Details
Get value of Fine Sync
Response
Acceptable
“000_%1” [CR]
%1
“0000 – 0031”
Unacceptable
“Error Code” [CR] --- When command is not available in the given
condition (such as being selected input)
“?” [CR] --- When unknown command is received
9.5.2 CR_TDOTS Command
Command
“CR_TDOTS” [CR]
Details
Get value of Total Dots
Response
Acceptable
“000_%1” [CR]
%1
“mmmm” – “nnnn”
(mmmm = Display area H + Position H)
(nnnn = Maximum value less than 140 MHz of Dot Clock)
Unacceptable
“Error Code” [CR] ------------------------ When command is not
available in the given condition (such as being selected input
“?” [CR] ------------------- When unknown command is received
9.5.3 CR_CLPPHASE Command
Command
“CR_CLPPHASE” [CR]
Details
Get value of Clamp Phase value
Response
Acceptable
“000_%1” [CR]
%1
“0001”~“nnnn”
(“nnnn” depends on input signal)
Unacceptable
“Error Code” [CR]
9.5.4 CR_H-POS Command
Command
“CR_H-POS” [CR]
Details
Get value of Horizontal Position
Response
Acceptable
“000_%1” [CR]
%1
“0000 – nnnn”
(nnnn = Total Dots – Display area H)
Unacceptable
“Error Code” [CR] ------ When command is not available in the
given condition (such as being selected input
“?” [CR] ------------------- When unknown command is received