-5-
This projector provides the following circuit protections to operate in safety. If the abnormality occurs inside the pro-
jector, it will automatically turn off by operating one of the following protection circuits.
Circuit Protections
Fuse
A fuse is located inside of the projector. When the POWER
indicator is not lightning, the fuse may be opened. Check
the fuse as following steps.
The fuse should be used with the following type;
Fuse Part No. : 323 027 2605
tYPe t10AH 250V
LItteL FuSe INc. tYPe 215010
How to replace the fuse
1. Turn the projector up and down.
. Loosen a screw on the fuse cover and open it.
3. Remove the fuse from fuse holder on the AC filter board.
to install the fuse, take reversed step in the above.
Fuse
Screw
Thermal protector
(SW901)
Thermal protectors (SW901, SW902)
There are the thermal protectors (SW901, SW90) inside of
the projector to detect the internal temperature rising abnor-
mally. When the internal temperature reaches near 100˚C,
the thermal protector cuts off the current supplied to the
power supply circuit.
To reset the thermal protection function, disconnect the AC
cord and leave the projector at the normal surrounding tem-
perature for about 45 minutes. The thermal protectors will
automatically reset when the internal temperature becomes
normal (around 60˚C).
Thermal protector
(SW90)
Summary of Contents for PLC-XTC50AL
Page 99: ... 99 IC Block Diagrams ISL98001 A D Converter IC2201 L3E06170 S H IC501 IC531 IC561 ...
Page 100: ... 100 IC Block Diagrams M62393 DAC IC7971 L3E07111 LCD DRIVE DIGITAL GAMMA IC401 ...
Page 101: ... 101 IC Block Diagrams NJM2671 Motor Controller IC7601 LC87F2G08A MCU IC4501 ...
Page 102: ... 102 IC Block Diagrams PW392 Scaler IC301 PW610 Keystone IC2301 ...
Page 103: ... 103 IC Block Diagrams TE7783 I O Expander IC4801 TPA3123 Audio Output IC5051 ...
Page 104: ... 104 IC Block Diagrams UPC324GR Ope Amp IC1423 ...
Page 158: ... KH7AM Nov 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...