PLC-XU305A/355A Expand Serial Command Functional Specifications
34/68
8.10.4 CF_AUTOSETUPKEYSTONE Command
Command
“CF_AUTOSETUPKEYSTONE_%1”[CR]
%1
“AUTO” ------------------- Set Auto Keystone function to Auto
“MANUAL” --------------- Set Auto Keystone function to Manual
“OFF” --------------------- Set Auto Keystone function to OFF
Details
Set Keystone function of Auto setup
This command is available in normal Power ON status.
Note) It is unable to set Keystone, PC ADJ. and Input search to OFF at once.
e.g. If projector receives Keystone OFF command while Auto PC ADJ. and Input
search are OFF, it returns error code “101”..
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]
8.10.5 CF_INPUTSEARCH Command
Command “CF_INPUTSEARCH_%1”[CR]
%1
“OFF” ------------------------- Set Input search operation to OFF
“ON1” ------------------------- Set Input search operation to On1
“ON2” ------------------------- Set Input search operation to On2
Details
Set Input search operation mode.
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Note) It is unable to set Keystone, PC ADJ. and Input search to OFF at once.
e.g. If projector receives Input search OFF command while Auto PC ADJ. and
Keystone are OFF, it returns error code “101”..
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.10.6 CF_AUTOSETUP
Command
“CF_AUTOSETUP_%1”[CR]
%1
“START” ------------------- Execute Auto Setup
Details
Execute Auto Setup
Note) CF commands does not execute while Auto setup is in process. If the
command is sent during this, projector returns error code “302”
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]
8.10.7 CF_BACKGND Command
Command
“CF_BACKGND_%1” [CR]
%1
“BLUE” -------------------- Select Blue Back
“USER” ------------------- Select User
“BLACK” ------------------ Select Black Back
“UP” ---------- Switch forward (Blue Back
→
User
→
Black Back
→
Blue Back)
“DN” --------- Switch backward (Blue Back
→
Black Back
→
User
→
Blue Back)
Details
Set Screen status for no signal.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
*When
%
1=”USER” is received, error code “101” is returned, in the case of
Capture non-practice.
Response
Acceptable
“000” [CR]
Unacceptable “Error Code” [CR]