37
Setting
For reducing power consumption as well as maintaining the lamp
life, the Power management function turns off the projection lamp
when the projector is not used for a certain period.
When this function is “On” and if the input signal is interrupted
and no button is pressed for more than 30 seconds, the timer
display with “No signal” appears on the screen. It starts the
countdown until the lamp is turned off. The countdown time is set
to five (5) minutes.
When the countdown time has elapsed, the lamp will be turned
off to cool itself down. The POWER indicator is blinking red during
the cooling-off period. When the lamp has been fully cooled down,
the POWER indicator changes to green blinking. In this condition,
the projection lamp can be turned on when the input signal is
reconnected or any button on the top control or remote control is
pressed.
Press the Point
8
or OK buttons to switch On/Off.
Power management
Power off confirmation
When this function is “On”, the confirmation dialog box with
“Power off?” is displayed when turning off the projector (p.19).
Press the Point
8
or OK buttons to switch On/Off.
The time left until
lamp off
Power management
Capture
This function enables you to capture an image being projected to
use it for the starting-up display or interval of presentations.
Select Capture and press the Point
8
or OK buttons. The
confirmation box appears and select [Yes] to capture the projected
image.
After capturing the projected image, go to the Logo function and
set it to “User”. Then the captured image will be displayed the
next time the projector is turned on.
To cancel the Capture function, select [No].
Capture
✔
Note:
• A signal from a computer can be captured up to XGA (1024 x 768).
• The image that has been adjusted in the Image adj. Menu cannot be captured.
• When capturing the image that has been adjusted by the Keystone function, the
adjusted data is automatically reset and the projector captures an image without
keystone correction.
• If the Capture function fails to capture an image or stops capturing halfway, the On-
Screen Menu returns to the Capture item.
• The Capture function cannot be operated with unsupported signals.
• When starting to capture a new image, the previously stored image is cleared even if
you cancel the capturing.
Select [Yes] to
stop capturing.
Select [Yes] to capture
the projected image.
Logo
This function decides on the starting-up display from among the
following options. Press the Point
8
or OK buttons to switch
between each mode.
User . . . . . Show the Image you captured.
Default . . . Show the factory-set logo.
Off . . . . . . . Show the Countdown display only.