-8-
Lamp Replacement
How to check Lamp used time
The LAMP REPLACE indicator will light yellow when
the total lamp used time (Corresponding value) reaches
3000 hours. This is to indicate that lamp replacement is
required.
The total lamp used time (Corresponding value) is cal-
culated by using the below expression,
Total lamp used time =
t
normal
+
t
high
x
t
normal
: used time in the Normal mode
t
high
: used time in the High and Auto mode
You can check the lamp used time following to the be-
low procedure.
1
Press and hold the
oN-oFF
button on the remote
control for more than 0 seconds.
2
The projector used time and lamp used time will be
displayed on the screen briefly as follows.
Lamp replacement
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1 Turn off the projector and disconnect the AC cord.
Remove 1 screw with a screwdriver and remove the lamp cover.
3 Loosen screws and pull out the lamp assembly by grasping the
handle.
4 Replace the lamp with a new one and tighten the screws back into
position. Make sure that the lamp is set properly. Replace the lamp
cover and tighten the screw.
5 Connect the AC cord to the projector and turn on.
6 Reset the lamp replacement counter, see below explanation.
Note
- The projector cannot be turned-on with lamp cover removed, because
when the lamp cover is removed, the lamp cover switch is also re-
leased to switch off the lamp circuit.
How to reset Lamp Replace Counter
1
Turn the projector on, press the
MENU
button and
the On-Screen Menu will appear. Press the
7
or
8
button
to move the red frame pointer to the Setting
Menu icon.
2
Press the
d
button
to move the red frame pointer to
the Lamp counter reset item and then press the
SE-
LECt
button. Select "Reset" and press the
SELECt
button. The message "Lamp replace counter Reset?"
is displayed. Move the pointer to [Yes] and then press
the
SELECt
button.
* Refer to owner's manual for further information.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may re-
sult in internal heat build up and short lamp life. We rec-
ommend cleaning the air filter after the projection lamp
is replaced.
Refer to “Air Filter Cleaning”.
Lamp
Lamp Cover
Screw
Screw
Handle
Screw
oRdER REPLACEMENt LAMP
Type No. Service Parts No.
POA-LMP106 610 33 3855
WARNING : tURN oFF tHE UV LAMP BEFoRE oPENING.
USE UV RAdIAtIoN EYE ANd SKIN PRotECtIoN dURING SERVICING.
Counter
Projector
525H
Lamp
High 150H
Normal 375H
Corresponding value 675H
total lamp used time
Projector used time
Summary of Contents for Think GAIA PLC-XE45
Page 28: ... 28 Electrical Adjustments 40 2 0 3 40 40 2 40 40 MAIN BOARD Test Points and Locations ...
Page 53: ... 53 BA7078 Sync Separator IC5301 IC Block Diagrams BA9743 DDC Control IC5651 ...
Page 54: ... 54 IC Block Diagrams L3E6100D D A S H LCD Driver IC501 IC531 IC561 FA5502 P F Control IC621 ...
Page 56: ... 56 IC Block Diagrams M62334 D A IC3571 NJW1141 Audio Control IC5001 ...
Page 57: ... 57 IC Block Diagrams STR Z2156A Power Switching IC631 uPD64012 Video Decoder IC101 ...
Page 87: ...KJ7 XE4500 87 Mechanical Parts List ...
Page 88: ... KJ7AC Feb 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...