OUTPUT TERMINALS
SW OUT Terminal
When recording, a pulse signal is output at the SW OUT
terminal.
This terminal is usually connected to the switch input
(SW IN) of devices like a camera switcher unit, or a quad
compressor.
SW OUT Terminal Output Setting
1
Press the MENU button to display the MAIN MENU.
2
Press the
l
(or
j
) button to select the
“2.DISPLAY/SW OUT SET” line, then press the
ENTER button.
ø
The (DISPLAY/SW OUT SET) menu appears.
<DISPLAY@SET>@@@@SET@UP
DATE@@@@@@@@@@@@@Y
TIME@@@@@@@@@@@@@Y
SPEED@@@@@@@@@@@@Y
ALARM@COUNT@@@@@@Y
<SW@OUT@SET>
TIMING@@@@@@@@@@@FIELD
FIELD@@@@@@@@@@@@1
2H@MODE@@@@@@@@@@Y
3
Press the
l
(or
j
) button until the “TIMING” setting
is highlighted, then press the ENTER button.
4
Press the
l
(or
j
) button to select the desired
output timing, then press the ENTER button.
FIELD. . . . . . 1 pulse is output after each set
number of fields.
FRAME . . . . 1 pulse is output after each set
number of frames.
5
Press the ENTER button.
6
Press the
l
(or
j
) button to select the desired pulse
signal interval (1, 2, 3, 4, 5, 10, 30 or 60), then press
the ENTER button.
œ
If “TIMING” is set to FRAME (see step
4
),
“FRAME” will be indicated instead of “FIELD”.
7
Press the ENTER button.
8
Press the
l
(or
j
) button to select the desired “2H
MODE” mode, then press the ENTER button.
Y. . . . . . . . . . When recording in 2-hour mode, a
pulse signal is output.
N. . . . . . . . . . When recording in 2-hour mode, a
pulse signal is not output.
9
Press the MENU EXIT button.
5V (H)
0V (L)
(Output impedance: 5.7 k
Ω
)
FIELD: 16.7 msec.
FRAME: 5 msec.
NB4Q/NA, NB4Q/NA2 (TLS-4960/TLS-4072 GB) Wed. Oct., 30/2002
44
English