NORMAL RECORDING
Recording Check
The image being recorded can be checked.
1
During recording, press the PLAY (REC CHECK)
button.
ø
The tape will be rewound and then played
back. The VCR will then return to the previous
recording mode.
NOTE:
œ
During recording check operations, recording is
suspended momentarily.
Clog Detection
This VCR is equipped with a clog detection function.
The recording quality is monitored automatically. When
the heads are dirty and the recording quality
deteriorates, the output at the WARNING OUT terminal
becomes 0V (Low), the “
m
” indicator flashes on the
digital display, and the buzzer sounds.
If in the (SET UP 3) menu, CLOG DETECT. is set to
“N”, the recording quality is not monitored.
NOTES:
œ
To cancel the “
m
” indicator display and reset the
WARNING OUT terminal output, press the STOP
button.
œ
Clog detection is not possible if recording in 3-hour
mode.
RR4Q/EX2 (TLS-9024P GB) Fri. Sept., 29/2000
16